Specification Guide
EPTH18/EPXTH18/NEPTH18/NEPXTH18/SEPTH18/SEPXTH18 Equipped with halogen lighting. Not
available with heat lamps. Shown with optional duct cover sold separately). Optional duct covers available
in standard and custom sizes.
Connection Diagram (54” - 66” Widths)
EUROSTYLE WALL MOUNT RANGE HOOD SPECIFICATIONS
*Recommended mounting
height is for optimum
performance.
Centerline
Of Hood
Wall Side
Electrical (2)
10" Outlet
Centered On
Hood Top
12 ⁄” 9 ⁄”
1 ¾”
Wall Side
7"
Electrical (2)
Centerline
Of Hood
12" Outlet
Centered On
Top Of Hood
1 ¾”
16 ½”
5 ½”
1 ¾”
18"
10"
8 ½”
18"
12"
7 ½"
U
L
CUS
R
(X) in part number indicates 27” depth
NEPTH18/NEPXTH18EPTH18/EPXTH18 SEPTH18/SEPXTH18
The transition shown (VP562 &
VP563) is installed in the hood
at the factory as a standard
item. It will be located in the
exact center of the duct cover
(left to right & front to rear).
Duct Cover
(Top of Hood)
10" Dia. or 12" Dia.
Transition Location
"Centered"
Connection Diagram (42" - 66" Widths) Recommended
Mounting Height
900 CFM B200 Dual & B100 Single Blower
(Top View)
VP562 Standard Transition
Installed (Front View)
1200 CFM Double B200 Dual Blowers
(Top View)
VP563 Standard Transition
Installed (Front View)
Electrical/Mechanical Specications For Blower Units
Model Volts Amps* Hz RPM
CFM
SP@0.0"
Equivalent CFM
•
CFM
SP@0.1"
CFM
SP@0.2"
CFM
SP@0.3"
Minimum Round
Duct Size
Sones
#
B200 Dual & B100 Single 115 4.4 60 1550 900 1350 804 725 655 10" (79 in.
2
) 6.3
Two B200 Duals 115 5.8 60 1550 1200 1800 1062 960 860 12" (113 in.
2
) 6.6
* Add 0.5 amp for each halogen light. Hood is available halogen lights (3 lights: 42" - 53", 4 lights: 54" - 66").
• BecausetheMagicLung
®
blowerusescentrifugalltrationratherthanconventionalbafeormeshlters,theMagicLung
®
blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efcientlythanotherthanotherltrationsystems.WhencomparingtheMagicLung
®
withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.
# RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0412A
OPTIONAL
DUCT
COVER
OPTIONAL
DUCT
COVER
OPTIONAL
DUCT
COVER