Installation Instructions

Page 5L112 1210A
Wall Side
7"
Electrical (2)
Centerline
Of Hood
12" Outlet
Centered On
Top Of Hood
1 ¾”
16 ½”
5 ½”
1 ¾”
18"
12"
7 ½"
Duct Cover
(Top of Hood)
10" Dia. or 12" Dia.
T r ansition Location
"Centered"
Brass Screws
A
Blower Wheel
B
Blower Housing
Installation Details Continued
18” Tall Euroline Pro Connection Diagram (54”- 66” Widths)
The transition shown (VP563)
is installed in the hood at the
factory as a standard item. It
will be located in the exact
center of the duct cover (left to
right & front to rear).
1200 CFM Double B200 Dual Blowers
(Top View)
VP563 Standard Transition
Installed (Front View)
8) Remove the duct cover from its packaging and remove the mounting screws from the base of the duct cover. Place
the duct cover on the top of the hood and secure it to the hood using the mounting screws previously removed. Lift
the hood and duct cover assembly to the location on the wall where it will be installed and lightly mark the wall with a
short, horizontal mark along the bottom edge of the hood.
9) Remove the hood and duct cover assembly from the wall. On the back side of the hood, measure the distance between
the bottom edge of the hood and the top edge of the wood mounting strip. Measure this distance above the horizontal
line made in Step 8 and lightly mark the wall with a level, horizontal line. Measure where the center (left to right) of the
hood will be and mark the upper, horizontal line on the wall with a short, vertical centerline.
7) Install an appropriate 1/2” UL listed electrical wire clamp through each motor box electrical opening on top of the
hood. Install electrical wiring from the service panel to the hood location for each motor box. Consult the connection
diagrams (above or on previous page) for further details on electrical placement. Extend wire(s) to the hood. Electrical
connection(s) will occur before the hood is installed on the wall.
5) Remove the blower shield(s) (A) by loosening the two brass screws on the bottom of the shield(s). Gently close the
back draft damper(s) from the top side of the hood. To remove the blower housing(s), unsnap the suitcase latches (B)
(one on each side of the housing). The housing(s) should be pulled forward and gently “tipped” to clear the blower
wheel(s) and then out of the hood.
6) Remove the three screws retaining the blower motor(s). Unplug
and remove the motor(s), taking care not to damage the blower
wheel(s). It is not necessary to remove the blower wheel from
the motor.
Warning: Make sure power is off and locked at the service disconnecting
means on the service panel during installation.
Model Volts Amps* Hz RPM
CFM
SP@0.0"
Equivalent CFM
CFM
SP@0.1"
CFM
SP@0.2"
CFM
SP@0.3"
Minimum Round
Duct Size
Sones
#
B100 Single 115 1.5 60 1550 300 450 273 245 225 6" (28 in.
2
) 5.4
B200 Dual 115 2.9 60 1550 600 900 531 480 430 8" (50 in.
2
) 6.5
B200 Dual & B100 Single 115 4.4 60 1550 900 1350 804 725 655 10" (79 in.
2
) 6.3
Two B200 Duals 115 5.8 60 1550 1200 1800 1062 960 860 12" (113 in.
2
) 6.6
* Add 2.5 amps for each warming light and 0.5 amp for each halogen light.
• BecausetheMagicLung
®
blowerusescentrifugalltrationratherthanconventionalbafeormeshlters,theMagicLung
®
blowercanhandlecookingequipmentwithhighercubicfeetperminute(CFM)requirementsandcandeliverequivalentCFMmuchmore
efcientlythanotherthanotherltrationsystems.WhencomparingtheMagicLung
®
withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.
#
RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.