18) TOP VENTED 10” x 10” SQUARE DUCT COVER APPLICATIONS ONLY. Insert the electrical wire from the service panel
through the electrical wire clamp on the motor box. Tighten the wire clamp. Cut a piece of duct the length of the duct
cover plus 2”. One end of the duct must be crimped to t inside the duct in the ceiling. Insert non-crimped end into
the exhaust collar on top of the hood and seal with duct tape. While securing the slack in the wire, lift the hood up to
the wall and hang the hood on the mounting strip, taking care to align the duct connection between the hood and the
ceiling. Secure the hood to the wood mounting strip by installing the screws (previously removed from the strip in
Step 13) into the pilot holes drilled in Step 15.
19) From inside the hood, using UL listed wire nuts, attach the “neutral” wire to the white lead inside the motor box, the
“hot” wire to the black lead inside the motor box, and the ground wire to the green lead inside the motor box.
Installation Details Continued
Warning: Do not operate hood without proper ground connection.
20) Plug the motors into the hood and reinstall the blower motor retaining screws that were previously removed in
Step 8.
21) Replace the blower housing and the blower shield. Make sure that the dampers open and close smoothly.
22) Refer to the Owner Maintenance Guide Operating Instructions for proper hood operation. Test all blower and light
functions to ensure they are operating properly.