User manual

14
EVERY 10-14 DAYS
Illustration 4:Switchoffapplianceandpulloutswitchingpowersupply.Pouroutsoiledwater.
Brushoffprecipitateddepositsinthelowerhousingandushout.Flushdiskstackwithwater.Fill
lowerhousingwithwateragain.RellwithVentahygieneagent.Fordosing,seescaleonbackof
bottle.
All residues in the lower housing and on the disk stack (white, green-yellowish or brownish precipi-
tation) do NOT impair the function of the Venta Airwasher. As a result of the addition of the hygiene
agent, trouble-free hygienic operation is guaranteed.
Dosage for models
LW 15 = Dosage for LW 14, LW 25 = Dosage for LW 24, LW 45 = Dosage for LW 44
See back of the bottle.
EVERY SIX MONTHS
Werecommendasix-monthlygeneralcleaningwiththeVentaCleaner.Accordingtothedegree
ofpollutionoftheairwasher,odorscanpossiblyariseduringcleaning.Pleaseprovideforfreshair
ventilationinthesecases.TheVentaCleanerwasespeciallydesignedtobecompatiblewithVenta
plastics,withoutattackingthem.Pleaseconsiderdirectionsforuseonbottle.
GENERAL CLEANING
Illustration 5:Switchofftheapplianceandpulloutswitchingpowersupply.Fortheopeningof
theupperhousing,pressonthelockinglatch(seearrows).
Illustration 6: It is absolutely necessary to consider the sequence during the opening of
the top cover: First pivot aside the two sides
1
+
2
(with light pressure) and after that pivot
out the two ribbed wings
3
+
4
.
Illustration 7:Removemainscableconnectorfromdriveunit
1
.Liftoutdriveunit
2
.Remove
mainscablefromholder
3
andpulloutthroughopeningintheupperhousing
4
.
Do not dismantle unit and switching power supply, do not immerse in water and do not bring
into contact with liquid!
Clean drive unit, fan blade and gearing with dry cloth!
Dismantled upper housing can be cleaned under owing water.
Dismantled upper housing must be completely dry before assembly!!!
Illustration 8:Placedriveunitintotheupperhousingincorrectalignment
1
.Pullmainscable
connectorupfromunderneaththroughtheopeningoftheupperhousing
2
andplugintodrive
unituntillatched
3
.Clipmainscableintoholder
4
.
Illustration 9: For the closing of the upper housing it is absolutely necessary to follow
the sequence: Place the external ends of the latches in the up position! First pivot up the two
ribbed wings
1
+
2
and press on the external ends of the latches (see rings). After that pivot
up the two side parts
3
+
4
and engage in latch.