Venta Airwasher User Manual Questio LW 15 For models LW 15/25/45 ns ? otline Ser vice H 8218 8 8 8 - 333 - LW 25 Read and save these important instructions LW 45 Das Original
Venta Airwasher User Manual For models LW 15 / 25 / 45 Contents: Important Safeguards--------------------------------------------------------------------------------------- 3 Letter from Venta-------------------------------------------------------------------------------------------- 4 Unpacking your Airwasher--------------------------------------------------------------------------------- 5 Before First Use---------------------------------------------------------------------------------------------- 6
Read all instructions: Important Safeguards QUESTIONS? Service Hotline 888-333-8218 Warning! It is important that you read, fully understand, and observe the following safety precautions and warnings. Read these instructions periodically. Careless or improper use of your Venta Airwasher may cause serious or even fatal injury. Keep this User Manual with your Airwasher. Be sure anyone using your Airwasher understands the information contained in this manual.
Dear Customer, Thank you for choosing the Venta Airwasher humidifier and purifier. The Venta Airwasher does away with the inconvenience of filters. With its humidification and purification system, Venta represents a revolutionary and worldwide unique technology. There are no filters to become contaminated. Water is the filter which is renewed daily. If maintained properly, the Venta Airwasher will consistently provide high humidifying and purifying performance for many years.
Unpacking your Airwasher 1 Gently remove the Venta Airwasher from its shipping carton. Keep the packaging if you plan to safely store your Venta Airwasher during the summer months, or in case of warranty repair. 2 Lift the upper housing and remove the protective shipping cardboard from the gear. and on the Warranty card 3 Note the serial # here: included with this User Manual. The serial # is located at the inside of the upper housing under the bar code.
Before First Use 1 P lace the unit upright on a firm, flat surface. For proper air circulation make sure the vented sides are at least 18-20” clear of any wall. Do not block airflow inlets and outlets. Unrestricted airflow will result in the best efficiency and performance of your Venta Airwasher. 2 Inspect the switching power supply to insure it is free of damages. 3 Make sure the upper housing is removed from the lower housing. 4 Place disk stack(s) into lower housing. 5 Add fresh tap water.
Operator panel 1 2 3 4 5 1 ON / OFF button 2 Operation indication ON / OFF Continuous lighting: ON No lighting: OFF Flashing: Fault (see Eliminating faults) 3 Fan stage display 1/2 (LW 15), 1/2 / 3 (LW 25/45) 4 Automatic shut-off display (see “Automatic shut-off”) 5 Fan stage selector button 1/2 (LW 15), 1/2 / 3 (LW 25/45) Daily Use and Operation •S witch on the appliance with button 1 . The operation display 2 lights up. The fan rotates on its lowest setting.
Main Components of the Venta Airwasher – Easy Access for Cleaning 1 Switch the motor off and unplug the switching power supply. 2 To open upper housing unit for easy access to components, simultaneously press both tabs next to the speed controls; “One-Click Technology” unlocks the upper housing. 3 Lower the 2 short (solid) sides. 4 Lower the 2 long (vented) sides. 5 Remove main cable connector from drive unit. 6 Using both hands, gently lift out the motor housing.
Maintenance and Cleaning Daily FILL with fresh tap water. Every 10-14 days RINSE lower housing and disk stack(s) with warm water. Wipe lower housing and fan blade with soft cloth. RECHARGE with the recommended dose of Venta Water Treatment Additive and fresh tap water. Twice a year CLEAN with ease. Use the Venta Cleaner periodically and the “one-click” technology to thoroughly clean the Venta Airwasher. See page 11 for instructions.
Venta Water Treatment Additive (WTA) Applications Venta Water Treatment Additive is designed to maintain hygienic conditions in the lower housing and to improve the evaporation process. The use of WTA is recommended for the best performance and efficiency of your Venta Airwasher. Proper usage will help prevent the formation of hard calcium deposits. Simply rinse and wipe out any sediment when changing the water.
Venta Cleaner Use every six (6) months or more frequently as needed. 1 F or thorough cleaning, fill lower housing with water, add the entire contents of the bottle and run the appliance on the lowest setting for approximately two (2) hours. 2 Empty lower housing and rinse disk stack(s) and lower housing with warm water. 3 Fill lower housing with water and add one dose of WTA. CAUTION! KEEP OUT OF REACH OF CHILDREN.
Venta Fragrances Distinctive fragrance blends are specially formulated for your Venta Airwasher and are water soluble. Directions: Add ½ - 1 capfuls of fragrance directly to the water in the lower housing. Effectiveness: Depending on room size, about 2-5 hours. KEEP OUT OF REACH OF CHILDREN . CAUTION! COMBUSTIBLE. Keep away from flame or heat. EYE AND SKIN IRRITANT. Avoid contact with eyes, skin, and clothing. Prolonged contact with skin may cause allergic reaction. DO NOT ingest.
•C leaning of disk stacks – Soaking the disk stacks in hot water with Venta Cleaner or white vinegar for approx. 30 minutes will help loosen any buildup of calcium or lime. Always rinse with warm tap water after cleaning. •V inegar and Water Solution – either a 50:50 or a 3:1 ratio of white vinegar and water can be used instead of the Venta Cleaning Solution. • Do not use the appliance in an environment with temperatures consistently over 95 degrees Fahrenheit.
Frequently Asked Questions Dear Venta Airwasher Customer: We thank you for the confidence you have placed in the Venta Airwasher. We are convinced that you will appreciate your Venta Airwasher’s trouble-free operation, its ease of cleaning and sturdy, simple technology. The following questions and answers will help you to fully understand the unique Venta Airwasher technology.
Frequently Asked Questions What happens if the water evaporates and the appliance continues to run? First and foremost, the Venta Airwasher is only humidifying and purifying when water is in the appliance. However, the water treatment additive holds dirt and dust particles down on the bottom of the lower housing. The LW 15 /25 /45 will shut off automatically as soon as there is insufficient water in the lower housing.
My Venta Airwasher appears to not be humidifying my room as desired? Our goal is to achieve 100% customer satisfaction. Initial product performance is largely based on room size and the overall humidity level of the contents within a room. Dry furnishings (textiles, leather, wood, books, etc.) will require a longer period of time to absorb moisture until their humidity level is increased to a satisfactory level.
Replacement of gear and coupling 1 P lace the rubber coupling into the locking ring so the rubber feet from the coupling hang below the ring. When placing the coupling and ring on the center shaft of the fan the rubber feet should line up with the notch marks on the fan. 2 Snap the ring and coupling into place. 3 With the gear laying on its side place it between the motor housing arms that suspend it above the fan.
Two (2) Year Limited Warranty Call Venta Customer Service to troubleshoot any issues, before attempting to return product to retailer. QUESTIONS? Service Hotline 888-333-8218 If you have any questions regarding this warranty please call 1-888-333-8218 or write to: Venta Airwasher Inc. US Headquarters 300 N Elizabeth St. Suite 220B Chicago, IL 60607 For product registration please return the enclosed Warranty Card.
Customer Service: Art.-No. 78500-36 Venta Airwasher Inc. US Headquarters 300 N Elizabeth St. Suite 220B Chicago, IL 60607 Toll Free: 1-888-333-8218 www.venta-airwasher.com e-mail: info@venta-usa.