Technical Specifications

ISLAND RANGE HOOD SPECIFICATIONS
Connection Diagram (60”- 66” Widths)
*Recommended mounting
height is for optimum
performance.
Recommended
Mounting Height*
Connection Diagram (36”- 54” Widths)
CIEH9 Equipped with halogen lighting. Not available with heat lamps. Shown with optional duct cover(s)
(sold separately). Optional duct covers available in standard and custom sizes.
Centerline
of Hood
Centerline
of Hood
Electrical
Vent Holes
¾”
2 ⁄”
5” x 16”
Exhaust
Opening
8” Transition
Opening 9”
Above Top
of Hood
9"
16"5"
8" Round 8" Round
9"
9"
9"
16"5"
8" Round 8" Round
11”
11”
Centerline
of Hood
Electrical (2)
Vent Holes
2 ⁄”
Centerline
of Hood
¾”
5” x 16”
Exhaust
Opening (2)
8” Transition
Opening (2)
9” Above Top
of Hood
550 CFM T200 Dual Blower
(Top View)
VP565 Transition
(Included)
Transition Installed
(Side View)
1100 CFM T2+200 Dual Blower
(Top View)
VP565 Transition
(2 Included)
Transition Installed
(Side View)
CIEH9
(550 CFM)
CIEH9
(1100 CFM)
Electrical/Mechanical Specications For Blower Units
Model Volts Amps* Hz RPM
CFM
SP@0.0"
Equivalent CFM
CFM
SP@0.1"
CFM
SP@0.2"
CFM
SP@0.3"
Minimum Round
Duct Size
Sones
#
T200 Island Dual 115 2.9 60 1550 550 900 507 471 431 8" (50 in.
2
) 6.0
* Add 0.5 amp for each halogen light. Hoods are available with halogen lights (4 lights: 36" - 59", 8 lights: 60" - 66", +2 lights for each 14" if over 66").
• BecausetheMagicLung
®
blowerusescentrifugalltrationratherthanconventionalbafeormeshlters,theMagicLung
®
blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efcientlythanotherthanotherltrationsystems.WhencomparingtheMagicLung
®
withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.
# RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0412A
U
L
CUS
R
1 ½”
1 ½”
Island Duct Cover
Mounting Holes
(Top View)
⁄” Dia.
OPTIONAL
DUCT
COVER
2 OPTIONAL
DUCT
COVERS
9"
9"
















