Technical Specifications

DESIGNER SERIES ISLAND RANGE HOOD
JCIH/C1 Equipped with halogen lighting. Not available with heat lamps. Optional duct covers available
in standard and custom sizes.
1100 CFM T400 Cluster Blower
(Top View)
*Recommended mounting
height is for optimum
performance.
9"
16"5"
8" Round 8" Round
12" Round
12" Round
11 ¼"
8" Round 8" Round 8" Round
VP564 Transition
(Included)
Transition Installed
(Side View)
550 CFM T200 Dual Blower
(Top View)
VP565 Transition
(Included)
Transition Installed
(Side View)
U
L
CUS
R
Connection Diagram (48" - 66" Widths)
Connection Diagram (36" - 54" Widths)
Recommended
Mounting Height*
Electrical/Mechanical Specications For Blower Units
Model Volts Amps* Hz RPM
CFM
SP@0.0"
Equivalent CFM
CFM
SP@0.1"
CFM
SP@0.2"
CFM
SP@0.3"
Minimum Round
Duct Size
Sones
#
T200 Island Dual 115 2.9 60 1550 550 900 507 471 431 8" (50 in.
2
) 6.0
T400 Island Cluster 115 5.8 60 1550 1100 1800 998 855 774 12" (113 in.
2
) 6.4
* Add 0.5 amp for each halogen light. Hood is available with halogen lights (one in each corner).
• BecausetheMagicLung
®
blowerusescentrifugalltrationratherthanconventionalbafeormeshlters,theMagicLung
®
blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efcientlythanotherthanotherltrationsystems.WhencomparingtheMagicLung
®
withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.
# RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 1113A
36"
30"









Centerline
of Hood
Electrical
6 ½”
Vent Holes
8” Transition
Opening
5” x 16”
Exhaust
Opening
Centerline
of Hood
Centerline
of Hood
8” Blower
Outlets
Centerline
of Hood
Electrical
6 ½”
10 ½”
Vent Holes
12” Transition
Opening