Technical Specifications

JDH/C1 Series Equipped with halogen lighting. Not available with heat lamps. Optional duct covers
available in standard and custom sizes.
DESIGNER SERIES WALL MOUNT RANGE HOOD
U
L
CUS
R
Centerline
Of Hood
Electrical
6" Outlet
Wall Side
Vent
Hole
1 7⁄8”
1 ¾”
5 ¼”
Centerline
Of Hood
Wall Side
Electrical (2)
10" Outlet
Centered On
Hood Top
12 ⁄” 9 ⁄”
1 ¾”
Wall Side
7"
Electrical (2)
Centerline
Of Hood
12" Outlet
Centered On
Top Of Hood
1 ¾”
16 ½”
5 ½”
1 ¾”
Electrical
1 ¾”
Centerline
of Hood
8” Outlet
Vent
Holes
5 ¼”5 ½”
Wall Side
36"
30"
*Recommended mounting
height is for optimum
performance.
Recommended
Mounting Height
Connection Diagrams (36" - 48" Widths)
Connection Diagram (48" - 60" Widths)
Connection Diagram (54" - 66" Widths)
B100 Single Blower
(Top View)
(Front View) B200 Dual Blower
(Top View)
(Front View)
900 CFM B200 Dual & B100 Single Blower
(Top View)
VP562 Standard Transition
Installed (Front View)
1200 CFM Double B200 Dual Blowers
(Top View)
VP563 Standard Transition
Installed (Front View)
Electrical/Mechanical Specications For Blower Units
Model Volts Amps* Hz RPM
CFM
SP@0.0"
Equivalent CFM
CFM
SP@0.1"
CFM
SP@0.2"
CFM
SP@0.3"
Minimum Round
Duct Size
Sones
#
B100 Single 115 1.5 60 1550 300 450 273 245 225 6" (28 in.
2
) 5.4
B200 Dual 115 2.9 60 1550 600 900 531 480 430 8" (50 in.
2
) 6.5
B200 Dual & B100 Single 115 4.4 60 1550 900 1350 804 725 655 VP562: 10" (79 in.
2
) 6.3
Two B200 Duals 115 5.8 60 1550 1200 1800 1062 960 860 VP563: 12" (113 in.
2
) 6.6
* Add 0.5 amp for each halogen light. Hoods are available with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66").
• BecausetheMagicLung
®
blowerusescentrifugalltrationratherthanconventionalbafeormeshlters,theMagicLung
®
blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efcientlythanotherthanotherltrationsystems.WhencomparingtheMagicLung
®
withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.
# RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0613A
10” Round 10” Round
8” Round
17 ½”
2”
8” Round 6” Round
12” Round 12” Round
16 ½”
8” Round 8” Round
8” Round
3”
VP562 Standard Transition
Included
VP563 Standard Transition
Included








 

