Installation Instructions

Page 3
JPH/C1 0414A
36"
30"
Installation Details
JPH/C1
1) Read all instructions thoroughly before beginning installation.
2) When installing a JPH/C1 wall mount range hood, it is recommended that the bottom edge of the hood be located no
more than 30" above the cooking surface for optimum performance.
3) IF THE HOOD IS TO BE “BACK VENTED”, PROCEED DIRECTLY TO STEP 4.
Consult the connection diagrams (on next page) for further details on exhaust outlet placement.
Install the duct(s) from the outside of the home to the ceiling over the exhaust outlet(s) on the hood. The end of the
duct(s) should extend 1" below the ceiling.
Use duct tape to seal all joints. A complete listing of available Vent-A-Hood ducting materials is provided on the back
page of this instruction sheet.
Transition heights are as follows:
Single Blower (B100): 6" round duct will connect directly to the top of the hood.
Dual Blower (B200): 8" round duct will connect directly to the top of the hood.
Single and Dual Blower (B100 & B200): 6" round duct will connect directly to the top of the hood; 8” round will
connect directly to the top of the hood. Optional 10" round combination
transition (VP562, sold separately) is 17 1/2" tall.
Two Dual Blowers (Two B200s): Two 8” round ducts connect directly to the top of the hood. Optional 12”
round combination transition (VP563, sold separately) is 16 1/2” tall.