Technical Specifications













VP562/VP563
transition
centers outlet
over top of hood
WALL MOUNT RANGE HOOD SPECIFICATIONS
*Recommended mounting
height is for optimum
performance.
Connection Diagram (42” - 60" Widths)
Connection Diagram (48” - 66" Widths)
900 CFM B200 Dual & B100 Single Blower
(Top View)
1200 CFM Double B200 Dual Blowers
(Top View)
6” Outlet
Vent
Hole
3 ¼”
Electrical
Centerline
of Hood
Wall Side
1 ¾”
1 ⁄”5 ¼”
Electrical
1 ¾”
Centerline
of Hood
8” Outlet
Vent
Holes
5 ¼”5 ½”
Wall Side
8” Outlet
6” Outlet
5 ¼”
Wall Side
Vent
Holes
Centerline
of Hood
Electrical (2)
5 ½”
7 ⁄”
1 ⁄”
7 ⁄”
1 ¾”
11” 11”
5 ½” 5 ½”
Wall Side
5 ¼”
1 ¾”
Electrical (2)
8” Outlet
Vent
Holes
8” Outlet
Centerline
of Hood
10” Round 10” Round
8” Round
17 ½”
2”
8” Round 6” Round
12” Round 12” Round
16 ½”
8” Round 8” Round
8” Round
3”
VP562 Transition (Optional) For B300
(B200 Dual Blower & B100 Single Blower)
VP563 Transition (Optional) For B400
(Double B200 Dual Blowers)
Connection Diagrams (30” - 48” Widths)
Recommended
Mounting Height*
U
L
CUS
R
10” OR 12”
Round
300 CFM B100 Single Blower
(Top View)
600 CFM B200 Dual Blower
(Top View)
NPH18/NPXH18/PRH18/PRXH18/SLH18/SLXH18 Equipped with halogen lighting. WBAR warming
light bar is available on selected models. X in part number indicates 27” depth.
NPH18/NPXH18 PRH18/PRXH18 SLH18/SLXH18
Electrical/Mechanical Specications For Blower Units
Model Volts Amps* Hz RPM
CFM
SP@0.0"
Equivalent CFM
CFM
SP@0.1"
CFM
SP@0.2"
CFM
SP@0.3"
Minimum Round
Duct Size
Sones
#
B100 Single 115 1.5 60 1550 300 450 273 245 225 6" (28 in.
2
) 5.4
B200 Dual 115 2.9 60 1550 600 900 531 480 430 8" (50 in.
2
) 6.5
B200 Dual & B100 Single 115 4.4 60 1550 900 1350 804 725 655 VP562: 10" (79 in.
2
) 6.3
Two B200 Duals 115 5.8 60 1550 1200 1800 1062 960 860 VP563: 12" (113 in.
2
) 6.6
* Add 2.5 amp for each warming light and 0.5 amp for each halogen light. Hoods are available with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66").
• BecausetheMagicLung
®
blowerusescentrifugalltrationratherthanconventionalbafeormeshlters,theMagicLung
®
blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more
efcientlythanotherthanotherltrationsystems.WhencomparingtheMagicLung
®
withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.
# RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0813A





