Technical Specifications

PRH18-M/PRXH18-M Equipped with halogen lighting. X in part number indicates 27” depth. M600 and
M1200 blowers are sold separately. Features stainless steel bafe lters.
WALL MOUNT RANGE HOOD SPECIFICATIONS
*Recommended mounting
height is for optimum
performance.
U
L
CUS
R
Recommended
Mounting Height*
Electrical/Mechanical Specications For Blower Units
Model Volts Amps* Hz
CFM
SP@0.0"
CFM
SP@0.1"
CFM
SP@0.25"
CFM
SP@0.5"
CFM
SP@0.75"
Minimum Round
Duct Size
M600 Single 115 5.0 60 630 625 615 600 580 6" (28 in.
2
)
M600 w/WHM300 Harness 115 5.0 60 302 300 295 288 278 6" (28 in.
2
)
M1200 Dual 115 10.0 60 1035 1015 1000 955 915 10" (79 in.
2
)
* Add 0.5 amp for each halogen light. Hoods are available with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54"-66").
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0514A
Available Widths
30", 36", 42", 48",
54", 60", & 66"
PRXH18-M/PRXH18-M






SPEED
CFM @ 0.1" S.P.
M600 WHM300* M1200
1 240 240 420
2 300 300 645
3 500 - 865
4 625 - 1015
* The WHM300 is a wiring harness that when used with
the M600 blower (sold separately) will disable the
blower speeds exceeding 300 CFM.
VP566 Transition
(Side View)
Single Blower
(Top View)
M1200 Connection Diagram
VP566 Transition
(Front Fiew)
Dual Blower with VP566 Transition
(Top View, see below for others)
M600 Connection Diagram






6" Round

Electrical




Electrical


10" Round


VP566 Transition Details (Included with M1200)