INTELLIGENT AXIAL FAN ACCEPTANCE CERTIFICATE user's manual The fan is duly recognized as serviceable. Approval mark Manufactured on (date) iFan iFan Move model VENTS iFan Sold (name and stamp of the trade company) Date of sale V01EN-(iFan)-03 www.ventilation-system.
Thank you for purchasing the fan made by VENTS. iFAN is an innovative extract bathroom fan enclosed into a compact casing. The unique technologies combined with smart electronics support the ideal comfort and microclimate in your house. The stylish fan design matches well with any modern interior. We do hope that you are happy with your fan's performance quality. ! WARNING Disconnect the fan from power mains prior to any connection, servicing and repair operations.
! WARNING Recycle at the end of the service life. Do not dispose the product with unsorted municipal trash. Read the present user's manual carefully before proceeding with installation works. Compliance with the manual requirements ensures reliable operation and long service life of the product. Keep the user's manual available as long as you use the product. You may need to re-read the information on the product servicing. DELIVERY SET The delivery set includes: 1. Fan - 1 pce; 2. Logo - 1 pce; 3.
Table 2 Spigot dia. Model 100 iFan / iFan Move 125 Speed Max. air capacity [m3/h] 24 Hours Silent Max 24 Hours Silent Max Noise level at 3m [dBA] 33 72 106 40 83 133 Air capacity, factory settings [m3/h] 17 22 31 17 21 32 Air capacity regulation range [m3/h] 33 ... 72 72 ... 106 40 ... 83 83 ...
PRODUCT MOUNTING The fan is designed for mounting into round Ø 100 or 125 mm air duct or installation into the ventilation shaft. The replaceable adapter of required size may be used to facilitate mounting. 100 125 The fan is equipped with a removable grille. Press the latches slightly to release the grille from the front cover. While installing the grille on the front cover back match the latches and respective slots in the cover and insert to click.
The fan casing has three round lowered tabs for cable entry. Cut out a hole at the most suitable place with a knife.
8 9 10 11 12 The fan may be connected to power mains by four wiring diagrams. The fan is compatible with 100-240 V / 50-60 Hz power mains. The iFAN Move has Li terminal for connection to the lamp up to 200W/230 V or 100 W/120 V. At this connection the fan will be switched on signal from the motion sensor.
Wiring diagram 1 L and N terminals are connected to live and neutral respectively. The fan is always in standby mode and does not run. As 24 HOURS Mode is activated the fan runs permanently at low speed to ensure minimum round-the-clock ventilation. As motion sensor is activated (for iFAN Move only) the fan switches to SILENT mode. After no motion is detected the fan reverts to standby mode. As humidity level increases the fan switches to MAX mode (by default) or to SILENT mode.
Wiring diagram 2 L and N terminals are connected to live and neutral respectively and L and LT terminals are joined by the jumper. The fan is always in SILENT mode. 24 Hours mode may not be activated. No matter of the signal from the motion sensor the fan operated in SILENT mode. As humidity level increases the fan switches to MAX mode (by default) or continues operation in SILENT mode (if adjusted by the user). After humidity level drops to standard level the fan reverts to SILENT mode.
Wiring diagram 3 L and N terminals are connected to live and neutral respectively. LT contact is connected to live through external switch, light switch. The fan is always in standby mode. As 24 HOURS Mode is activated the fan runs permanently at low speed to ensure minimum round-the-clock ventilation. As the external switch is closed the fan switches to SILENT mode. After the external switch is off the fan reverts to standby mode.
Wiring diagram 4 L and N terminals are connected to live and neutral respectively. LT terminal is connected to live through the external momentary switch that is activated by opening a door. The fan is in standby mode and does not run. As 24 HOURS Mode is activated the fan runs permanently at low speed to ensure minimum round-the-clock ventilation. As the external momentary switch is closed the fan switches to SILENT mode for the period adjusted in the off-delay timer.
FAN ADJUSTMENTS The fan is adjusted at the factory and is ready for operation. It is a fully operable product without extra adjustments. However if you want to adjust the fan according to your needs, please follow the instruction below. You can always reset to the factory settings.
You can adjust the fan both with the control panel located on the fan or with the remote controller. The remote controller has 3 m effective range. To attain the maximum effective range response direct the remote controller straight to the fan. ATTENTION! The fan covers of Melange, Ruby Star, Champagne, Silver colours provide high signal conductivity from the remote controller and do not influence the signal transferability. The covers of Graphite, Violet Topaz or Black Sapphire may suppress the signals.
SILENT MODE SPEED ADJUSTMENT By default the speed is 83/72 m3/h. To set the speed: Press the buttons "3CP" and "4CP" on the control panel. Press the buttons "4RC" on the remote controller. Press the buttons "3CP", "4CP" or "4RC" once to display the current air capacity. MAX MODE SPEED ADJUSTMENT By default the speed is 97/82 m3/h. To set the speed: Press and hold the button "7CP" and then press the buttons "3CP" and "4CP" on the control panel. Press the buttons "5RC" on the remote controller.
HUMIDITY EXTRACTION MODE ADJUSTMENT The default time is 30 minutes. After crossing the humidity set point the fan switches to higher speed to extract excessive humidity. After the humidity level stabilization the timer is activated and the fan runs for the set time period to enable total extraction of the excessive humidity and then it reverts to the previous operation mode. If humidity rises less than by 20% for 10 minutes, the timer countdown is 15 minutes.
TURN-ON DELAY TIMER ADJUSTMENT The default time is 0 minutes. If you have to visit the bathroom often, you can adjust the turn-on delay timer to avoid the fan unnecessary switching. After humidity increases or after signal from the external switch/motion sensor, the fan switches to higher speed not immediately, but in some time period. To adjust the turn-on delay timer: Press and hold the button "5CP" and press the button "2CP" in cycles on the control panel.
ACTIVATION 24 HOURS MODE In this mode the fan has minimum air capacity before the humidity sensor, motion sensor or external switch is activated. To activate 24 HOURS mode: Press the button "6CP" on the control panel. Press the button "10RC" on the remote controller. This function is not available for the wiring diagram 2. EXTRA FUNCTION - PAUSE This function is controlled from the remote controller only.
RESET TO FACTORY SETTINGS Push The fan side panel incorporates a built-in manual power slide switch. Turn the fan off with this power switch, press the button "MODE" on the control panel, hold this button and switch the fan on with this slide power switch. When the fan turns on, hold the button "MODE" within 5 seconds until the light under the button stops blinking green.
3 4 5 6 STORAGE AND TRANSPORTATION RULES Transport the product by any transportation vehicle in the manufacturer's original package. Store the delivered product in the manufacturer's original packing box in a dry ventilated premise with the temperature range from +50C up to + 400C and relative humidity less than 80%. The storage environment must not contain dust, acid or alkali vapours that may cause corrosion of the product parts.
OPERATION RULES The fan is designed for connection to single-phase ac 100-240 V / 50-60 Hz power mains. The fan is designed for continuous operation always connected to power mains. The fan is rated for operation at the ambient temperature ranging from +1°C to +45°C. The fan is double-insulated and requires no grounding. The fan complies with the requirements according to the EU norms and directives, to the relevant EU-Low Voltage Equipment Directives, EU-Directives on Electromagnetic Compatibility.
- in case of non-timely technical maintenance of the product by the customer (dust, mud, oil condensate, foreign particles); - in case of causing external damage to the product by the customer ('damage' shall not apply to external changes of the product required for the product mounting); - in case of altering the product design or further reworking of the product; - in case of replacing and using parts, units and components of the product not prescribed by the manufacturing company; - in case of other use