ERV 80 EC Specs

PRODUCT
SPECIFICATIONS
TECHNICAL
DATA
Tel: 888-640-0925
513-348-3853
Fax: 513-268-4597
Sales@ventsus.com
VentsUS.com
11013 Kenwood Road,
Cincinnati, Ohio 45242
Frigate ERV 80 EC
ENERGY RECOVERY VENTILATION
2018/10
PERFORMANCE
Gross Airow - CFM
Ext. Dierential Pressure - in. W.G.
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
0 10 20 30 40 50 60 70 80 90
Supply
Exhaust
SOUND
1.4 Sones (30 L/s @ 0.2 in. W.G.)
MODEL Volts Max. Watts Max. Amps
ERV 80 EC 120V, 60Hz 61 0.9
EXTERNAL STATIC PRESSURE
NET SUPPLY
AIR FLOW
GROSS AIR FLOW
POWER
SUPPLY EXHAUST
Pa in. W.G. L/s CFM L/s CFM L/s CFM Watts
25 0.1 38 81 40 84 42 88 61
50 0.2 35 74 36 76 38 81 61
75 0.3 32 67 33 69 35 74 61
100 0.4 29 61 30 63 31 65 60
125 0.5 26 54 26 56 27 57 61
150 0.6 22 46 23 48 22 47 60
175 0.7 17 37 18 38 17 36 58
200 0.8 12 26 13 27 12 26 59
225 0.9 8 16 7 14 8 17 55
MODE SUPPLY
TEMPERATURE
NET AIR FLOW AVERAGE POWER SENSIBLE
RECOVERY
EFFICIENCY
APPARENT
SENSIBLE
EFFECTIVENESS
NET
MOISTURE
TRANSFER
°C °F L/s CFM (Watts) SRE (%) ASEF (%)
HEATING
0 32 20 42 25 73 82 0.46
0 32 25 53 38 69 79 0.47
0 32 30 63 49 68 78 0.45
**Total Recovery Efficiency
COOLING 35 95 20 42 25 54.5 ** 72 0.49
** Indicates total recovery efficiency, not sensible recovery efficiency