Owner's Manual

The fans are in-line mixed type fans designed for
extract ventilation of rooms heated in winter time. Fans
are made of white plastic. Delivery set includes:
1. Fan - 1;
2. Screws with plugs - 4;
3. Users manual;
4. Packing box.
Fans are compatible with 3 15/16" (100 mm),
415/16" (125 mm), 57/8" (150 mm), 65/16" (160 mm),
77/8" (200 mm) diameter ducts.
are equipped with higher-power motor
Fans are supplied with an internal three-position
speed switch (fig. 3), which provides fan operation in
three different function modes:
“0”– turned off, the fan is not operating;
“I” – the fan is operating at minimum speed;
“II” – the fan is operating at maximum speed.
Fans may be mounted either vertically or horizontally
(fig. 1). Fans may be used either separately or as part of
a set for parallel or in-line mounting (fig. 2). Parts that
come with connecting units are delivered separately.
An air duct at least 40 inches (1 meter) long should be
connected to an inlet flange in case of horizontal fan
mounting; a canopy should be installed on an inlet flange
in case of vertical mounting. Outlet flange should always
be connected to an air duct. Mounting is shown on
Fig. 4-12. Air motion must coincide with direction of i
ndicator on the fan case.
Input: 120V AC 60Hz.
Fans are designed for
continuous operation without disconnection from network.
Protection rating from access to dangerous parts and
water penetration is IPX4. Fans can be operated at
ambient temperatures between +37 ° F and +107 ° F
(for the details, please, see the manufacturer's catalog).
Fan construction is constantly being improved, that is
why some models can differ slightly from those described
in this manual models.
S models .
Scheme of fan connection to the
power network is shown on Fig. 3.
WARRANTY
Production meets standard operating
requirements in the territory of the USA and Canada.
Manufacturer guarantees normal operation of the
unit for 60 months from the date of resale, subject to
the compliance with transport, storage, mounting
and operation rules.
If proof of sales date is absent, warranty period is
calculated from the production date.
In case of failure due to faulty equipment
warranty period, the consumer has the right to
exchange it.
The unit can be exchanged at the following
address:
Bodor Vents, LLC
11013 Kenwood Road Cincinnati, Ohio 45242
Phone: (513)348-3853
e-mail: bodorvents@cinci.rr.com
Manufacturer is not responsible for damages
resulting from misuse of the unit or gross
mechanical alteration.
Owner of the unit must follow the guidelines set
forth in the manual.
Fan surfaces need to be cleaned of dirt and dust
regularly by using a soft, wet cloth and mild detergent
(Fig. 13-18).
Do not allow liquids to come in contact with the
electric motor. Wipe surfaces dry after cleaning.
Recylcle at the end of unit's
service life.
Do not dispose of with other trash.