VENTS Dryer Booster In Line Centrifugal Fan Leaflet

VK PS Series
DRYER BOOSTER FANS
VK PS booster fans can be used to exceed the maximum 25 ft.
and allow complex duct runs. The fan should be at least 15 ft. from
the dryer as close as possible where the duct terminates. Installed
closer than 15 ft. from the back of the dryer, the use of VENTS
DLT454 Lint Trap is recommended as the fan could pull lint into the
fan body causing clogging. Lint trap should be installed in the dryer
duct just above the dryer. Please refer to the installation manual for
the correct angle of pressure switch.
• Installed Pressure Switch
• Ducts: 4”, 5”, 6”
• High static pressure
applications
• Backward curved centrifugal
impeller
• External rotor motor
with thermal overload
protection
• Ideal for long duct runs
• Vibration free operation
• Energy efficient
• Maintenance free
• Corrosion resistant
• UV resistant, UL94 certified
plastic
• Pre-wired and supplied with
mounting bracket for easy
installation
• ETL listed
Applications
Benefits
For Dryer Boost Application
Tel: 888-640-0925
513-348-3853
Fax: 513-268-4597
Sales@ventsus.com
VentsUS.com
11013 Kenwood Road,
Cincinnati, Ohio 45242
VENTS VK PS Series dryer booster fan has been specially designed
to solve dryer vent problems where more airflow is needed. VK PS
dryer booster fans make dryers run more efficiently, save energy
by reducing drying time, and limit lint and moisture problems. The
pre-installed pressure switch runs in 10 minute repeate cycles.
Every 10 minutes the booster fan stops for 15 seconds. If the
pressure still exists, another cycle begins. If the dryer stops during
the cycle, the booster fan will complete the 10 minute cycle that
it had started before the dryer stopped. The extra venting helps
to keep the duct lint free and to clear any remaining moisture.The
fans are fitted with backward curved centrifugal impeller, which
prevents lint from getting stuck in the fan. Feature powerful sealed
external rotor motor with lifelong bearings and thermal protection.
This powerful combination enables the VENTS VK PS fans to deliver
exceptional airflow performances even in long duct runs.
Designed to vent up to 150 ft. duct work.

Summary of content (2 pages)