Specifications
6  Monitor ISM/xL™ Hardware Guide 
22-0375 rev1.1 
No Commands (Simple Access) 
Door Mode  <Login>  Notes 
Card Only  <card>  If a UID/PIN is entered, it will be ignored 
Card & PIN  <card> <pin>  UID is not required since the card 
automatically identifies the <uid> 
Card or UID/PIN  <card> or <uid> <pin>   
UID/PIN Only  <uid> <pin>  If card is presented, it will be ignored. 
  <uid> – User ID 
With Commands 
Door Mode  <cmd> <Login>  Notes 
Card Only  <cmd> <card>  If a UID/PIN is entered, it will be ignored 
Card & PIN  <cmd> <card> <pin>  Card badging must always be done before 
the PIN entry. 
Card or UID/PIN  <cmd> <card> or 
<cmd> # <uid> <pin> 
Pressing “#” is required between the 
command and uid/pin entry. 
UID/PIN Only  <cmd> # <uid> <pin>  Pressing “#” is required between the 
command and uid/pin entry. (Note 
<cmd> # <pin> in PIN Only systems) 
  <cmd> – Command 
NOTES:
<login> requires your <card> OR alternatively, your uid/pin. 
E.g. <3 digit UID> <4 digit PIN>. Leading zeros cannot be omitted in UID or PIN. 
Example 1: Arm area using card – enter <  3 card > 
Example 2: Work late for 3 hours using uid/pin – enter <  6 3 # 001 1234 > for user 001 with pin 1234 
Example 3: Access area without using card – enter < 001 1234 > for user 001 with pin 1234. 
Using Duress Pin at Arming Station
•  A Duress Pin (reversing last 2 digits of a user’s pin entered on the keypad to transmit a potential hold-up 
condition) can be used at an Arming Station if the duress feature has been enabled in the System Group. 
LED Indicators
Work Late LED 
•  Turns on if the area the Arming Station is assigned to is scheduled. 
•  Turns on solid 15 minutes before scheduled closing time. 
•  Does not operate if the area is not scheduled. 
Door State LED 
•  Solid red if the door is locked. 
•  Solid green if the door is unlocked. 
•  Flashing red during disarming if there had been an alarm in the area. 
Armed LED 
•  When activated, armed LED only stays on for the duration of the area’s Entry/Exit Delay during the following area 
arming state changes. 
–  Momentarily solid green when the area is disarmed to OFF. 
–  Momentarily solid red when the area is armed to STAY. 
–  Momentarily flashing red when the area is armed to Fully ON. 
Arming Station Internal Buzzer Indications
•  Entry/Exit tones same as LCD keypad. 
•  Fire Siren – intermittent tone. 
•  Burglary Siren – steady tone. 
•  Bad Command Entry – double short beeps. 
•  Command accepted – single long beep. 
•  Unauthorized to perform command – double long beep. 