Specifications
8  Monitor ISM/xL™ Hardware Guide 
22-0375 rev1.1 
2 Zone Wiring cont. 
ORANGE Protection Point Input # 1
PURPLE Protection Point Input # 2
BLACK Input point 
common connection. 
Output power source 
negative.  
RED 
GREEN 
YELLOW 
BLACK 
"
B
"
C
o
n
n
e
c
t
BLUE Switching to GND Output.
To output driven device.
E.g. electronic siren with 
built in driver.
Input # 1 e.g. Main entrance door contact.
Programmed and wired as normally open 
with 2.2K end of line resistor.
Input # 2 e.g. Motion detector alarm contact.
Programmed and wired as normally closed.
Protection Input points 1 & 2 and Output Wiring Example 
(+)(-- )
2.2 K
NC NO
CM
NC NO
CM
Keypad
Base
(back view)
Power 
Supply
(+)
(-- )
Siren
Separate Data
A,B Cable
Separate 
Power Cable
M
O
D
U
L
E
B
U
S
Common 
Negative 
Reference