Specifications
16  Monitor ISM/xL™ Hardware Guide 
22-0375 rev1.1 
SENSOR 
CATEGORY
DESCRIPTION DEFAULT 
SETTINGS
Cnt  Door Window Contact (surface mount) 
-  also used as an RF transmitter for hard wire inputs 
-  e.g. Overhead Door Contacts 
3.
. 
FrP Fire Pull  3. . 
Frz  Freeze Temperature Detector  3.. 
Gls  Glass Break Detector  3.. 
HKP  Hand Held Keypad  0. . 
PIR  Passive Infra-red Detector  3.. 
Pnc  Panic Pendant OR Hand Held Double Button Panic  0. . 
Rcn Recessed Contact  3.. 
RoR  Rate of Rise Detector  3. . 
Smk Smoke Detector  3. . 
SoS  Shock and Sound Detector  3.. 
???  Unknown sensor type – delete this sensor and re-learn 
Testing (Signal Strength) 
•  Use the Service PIN to go to the TEST menu. 
• Select App for application module and then W/L for wireless. 
• Select Scan. Activate a sensor. 
•  The screen will display information about each sensor it receives. E.g. Cnt56DB5 (door/window contact and its 
address), 
014 (input #14), 80 02 4 (sensor transmit codes). 
•  Press XESC escape to return to the TEST screen. Press Signal. 
•  Activate a sensor. Screen indicates signal strength of sensor it receives. E.g. “Strength is 8 !”. Signal strength of 
7 to 8 is acceptable. Signal strength of 6 or less is poor to unacceptable. The input point # transmitting will also 
indicate: 
(Tx: 014). 
•  Another method to check if a sensor is transmitting is to stand near the RF module holding a sensor and activate 
the sensor. The large green LED, visible through the module’s cover will flash upon activating the sensor to 
indicate signal transmission. 
•  RF Module sensor inputs OK or Not OK and Tamper can be checked in System Status/Area/Points. 
•  RF Module, hand held keypad(s) and sensor status can be checked in System Status under App – Wireless 
using the left or right arrow LCD keypad keys for conditions such as low battery, sensor loss. Disregard any codes 
in lower right corner of these screens. 