Specifications
42  Monitor ISM/xL™ Hardware Guide 
22-0375 rev1.1 
Communication Modules 
Printer 
Printer Serial Port Male DB25 Connector 
(viewed from the connections side)
Pin 3 - WHITE
Pin 20 - RED
Pin 5 - BROWN
Pin 7 - BLACK
1432
56
1432
5
1432
5
Tamper Pins 
F1
1/2 AMP
P/N 342-3356
Bus communications 
indicator 
0V
CTS
RTS
RX
TX
Not Used
Printer
TB4
TB2
Printer Module
1432
Module Bus
Data A
Data B
(+) 12V
0V
red
green
yellow
black
Current rating = 61mA 
5 digit serial number 
to program in Module 
Programming
XXXXX
Not Used
TB3
PIN 1 - 13
PIN 14 - 25
Printer Programming 
(using LCD Keypad only) 
NOTE: The term “HSC” is used to access 
the printer abilities in this application. 
HSC is a proprietary communications of CSG 
Security Inc. and not used in all markets.
• This module has no inputs or outputs. 
• Enter the module’s 5-digit address in 
Module programming. 
• Enable the tamper and make 
input/output values “0”. Leave 
defaulted to area 1 and leave all other 
selections defaulted. 
• Press Save. Exit module programming 
and then go back to module 
programming and the same address. 
This initializes the module. 
• Check Prn? (Printer) enabled: . 
Screen changes to “HSC/Printer 
Module Rebooting”. Press OK. Return 
to Printer programming screen. 
• Enter baud rate for printer: 
0 = 1200, 1 = 2400, 2 = 4800,  
3 = 9600, 4 = 19200. 
•  If CTS is enabled (), only users with 
authority to view History can start the 
printer if it runs out of paper, etc. If it is 
disabled (), simply fixing the printer 
problem (e.g. load paper) will re-start 
the printer. Press Save. 
Printer Specifications 
Type: RS232 serial 80 columns (or more) 
Data Setup: 1 start bit, 1 stop bit, 8 data 
bits, no parity, baud rate selectable 
(recommend 1200), hardware 
handshake. 
Printer Connection: female DB25. 
Settings for Epson LX300
(P/N 400-0810)
Character spacing = 10cpi, Shape of zero 
= 0, Skip-over-perforation = Off, 
Character table = PC 437, Auto line feed 
= Off, Page length = 11 inches, Auto tear 
off = Off, Tractor = Single, Interface = 
Serial, Bit rate = 1200 bps (baud), Parity 
= None, Data length = 8 bit, EXT/ACK = 
On, Software = ESC/P, Auto CR = Off. 
To start the Printer
• Enter the History menu in the main 
menus and select “Category” and 
“App” for application module. 
• Select “HSC”. 
• Select Printer or Lang for the 
language the printer will print in. 
• When selecting printer press Start to 
start the printer. 
•  Press Pause to stop printing or 
Resume to commence printing.
• Press Cncl to cancel a backlog of 
pending messages. 
• Press Plog to reprint the entire log in 
the History menu. 
Wiring Printer Connection to a PC 
Serial Port (TB 4: Printer Port) 
(when the customer wants the history to 
go directly to a computer instead of a 
printer) 
•
 In the module settings, turn off the 
  CTS option in the Printer Menu. 
  In the terminal program (‘Terminal.exe’ 
in Windows for Workgroups; ‘Hyper 
Terminal’ in Windows ’95/98) set the 
baud rate for the same speed as the 
  module (typically 1200) and turn off
hardware flow control. 
• Only 2 connections are required: 
•  Connect Tx on the module to Rx on 
the PC serial port 9pin 3 on DB25; 
pin 2 on DB9). 
•  Connect OV/Gnd on the module to 
0V/Gnd for the serial port (pin 7 on 
DB25; pin 5 on DB9). 
Refer to Installation Instructions P/N 22-0370 for further information. 