Specifications
22-0375 rev1.1  Monitor ISM/xL™ Hardware Guide  5 
Wiring 
1
2
3
4
5
6
7
8
9
0
#
1432
56
 (+)5/12VDC
 Green LED
 Red LED
Data 1 Clock
Ground 0V
Data 0
 Reader
...
 5V
 12V
 Reader
Voltage
Jumper
Red Ensure power jumper set to 12V
Orange Controls Door Locked/Unlocked LED 
Blue 
or Yellow  Keypad area control communications.  
White Data 1 
Green 
Data 0 
Black 
GND + Shield Wire 
Arming Station 
current rating = 
80mA
Maximum cable distance from 2 Dr Access Module to 
Arming Station is 500 feet. 
Reader Connections at Door Access Module
Arming Station Internal Buzzer follows LCD 
Keypad Tones
e.g. Entry/Exit Delay, Work Late Tones etc. as 
well as door access conditions e.g. Door Forced.
NOTE: 
NOTE: the Keypad area control communications 
wire must be connected or the Work Late and 
Armed LEDs will flash back and forth. 111-8240 
GProxI wire is blue. 111-8270 (switch plate) or 
111-8267 (mullion) GProxII wire is yellow.
Keypad Command Entries 
<login> represents the form of user identification used e.g. badging card and or ID – PIN entry. 
Key Sequence  Command 
< login > only  Access (momentary unlock of door) 
 1 <login> 
Turn area off 
 1 0 <login> 
Turn all areas off 
 2 <login> 
Turn area to stay mode 
 3 <login> 
Turn area on 
 3 0 <login> 
Turn all areas on 
 5 <login> 
Toggle between Lock Door and Unlock Door & Disarm area 
Door commands or if door is locked and area armed – unlocked and area disarmed. 
 6 <login> 
Work Late in this area by 2 hours at a time from the current time. Scheduled 
area only. 
This command can only be used again at the end of the first entered 2 
hours when the arming station will indicate closing time again with the work late LED 
flashing and tones. At that time, this command can be used again to extend the 
closing time another 2 hours. 
 6 n <login> 
Work Late in this area for n hours where n = 1…9. Scheduled area only. 
 7 <login> 
Activate armed state LED display for approximately 20 seconds 
To determine arming station’s area condition. Armed LED indicates for 20 sec: 
green for OFF, red for STAY and flashing red for ON. 
 9 <login> 
Silence alarm (in all areas) 
# #  Cancel any keys previously entered 
#  If performing a “” command with UID/PIN, insert a "#" key between 
command and UID/PIN entry (e.g. “ 1 # 341 1234 ” for user 341, pin=1234 
trying to arm the area 1). 