TDS

TECHNICAL DATA SHEET
Effective: April 8, 2019
Page 1 of 1
(866) 843-8453 | halsteadintl.com
PHYSICAL PROPERTIES & PACKAGING (DRYBACK RESILIENT FLOORING) - 2.5MM GAUGE / 22MIL WEAR LAYER
Collection
Construction
Size
Gauge
Wear Layer
Use
Profile
Finish
Embossing(s)
Coverage/Carton
Coverage/Pallet
Limited Warranty
STANDARDS MANUFACTURING & USAGE (ASTM F1700)
Standard
Description
Requirements
Results
ASTM F1700
Classification
Refer to Standard
Class III, Type B
ASTM F386
Thickness
Tolerance: ±0.005” vs. Nominal
Passes Requirements
ASTM F410
Wear Layer Thickness
Commercial Classification:
20mil (0.5mm)
Passes Requirements
ASTM F2421
Size & Squareness
Size, Tolerance: ±0.016"/Linear Foot vs. Nominal
Squareness: ≤0.010"
Passes Requirements
ASTM F1914
Residual Indentation
Average <8%
Maximum Any Sample ≤10%
Surpasses Requirements
ASTM F137
Flexibility
No cracks/breaks (1”/25.4mm Mandrel)
Surpasses Requirements
ASTM F2199
Dimensional Stability
≤0.020"/Linear Foot
Surpasses Requirements
ASTM F925
Chemical Resistance
No more than “Slight Change”
Surpasses Requirements
ASTM F1514
Resistance to Heat
Average ΔΕ < 8.0
Surpasses Requirements
ASTM F1515
Resistance to Light
Average ΔΕ < 8.0
Surpasses Requirements
STANDARDS SAFETY & PERFORMANCE
Standard
Description
Requirements
Results
ASTM E648
Critical Radiant Flux (Radiant Panel)
Class I: ≥ 0.45 W/cm
2
Passes Requirements
1
ASTM E662
Smoke Density
Flaming & Non-Flaming ≤ 450
Passes Requirements
2
ASTM F963
Heavy Metals
Refer to Standard
Passes Requirements
ASTM D7823
Phthalates
Refer to CPSIA
3
Passes Requirements
ASTM D2047
Coefficient of Friction / Slip Resistance
N/A (No Official Requirements)
≥0.6 (Dry)
ASTM F970
Static Load
±0.005”, 250-Lbs. Load
Passes Requirements
SIM Test
Static Load Limit
Test to Limit (±0.005”)
1,000 psi
CERTIFICATIONS
Standard
Description
FloorScore
®
This product is FloorScore
®
Certified (Certificate #SCS-FS-02874) and has thus been found to comply with the volatile organic
compound emissions criteria of the California Section 01350 standard.
Notes
1) ASTM E648 - Critical Radiant Flux (Radiant Panel): Passes Requirements for Class I per International Building Code (IBC) 2018 & NFPA 101 Life Safety Code.
2) ASTM E662 - Smoke Density: 450 is the limit established by many state, county, and/or local building and/or fire codes but is not set as a limit for (resilient) flooring products
nationwide. Thus, Smoke Density requirements for flooring products may vary from jurisdiction to jurisdiction. Consult your building inspector / fire marshal to learn more.
3) ASTM D7823 - Phthalates: CPSIA = Consumer Product Safety Improvement Act.
*Ultra-Fresh is a registered trademark of Thomson Research Associates, Inc.

Summary of content (1 pages)