TDS
TECHNICAL DATA SHEET
Effective: April 8, 2019
Page 1 of 1
(866) 843-8453 | halsteadintl.com
PHYSICAL PROPERTIES & PACKAGING (DRYBACK RESILIENT FLOORING) - 2.5MM GAUGE / 22MIL WEAR LAYER
Collection
VergePRO Plank
Construction
Solid Vinyl Tile/LVT
Size
7.25” x 48” (184.2mm x 1219.2mm)
Gauge
2.5mm (0.098”)
Wear Layer
22mil (0.55mm)
Use
Commercial
Profile
Square Edge
Finish
ScratchProtect
TM
w/Ultra-Fresh
Embossing(s)
Natural Timber
Coverage/Carton
16 pieces – 38.67 Sq.Ft. (3.59 Sq.M.)
Coverage/Pallet
35 cartons – 1,353.45 Sq.Ft. (125.74 Sq.M.)
Limited Warranty
Commercial - 15 Years
Residential - Lifetime
STANDARDS – MANUFACTURING & USAGE (ASTM F1700)
Standard
Description
Requirements
Results
ASTM F1700
Classification
Refer to Standard
Class III, Type B
ASTM F386
Thickness
Tolerance: ±0.005” vs. Nominal
Passes Requirements
ASTM F410
Wear Layer Thickness
Commercial Classification:
≥ 20mil (0.5mm)
Passes Requirements
ASTM F2421
Size & Squareness
Size, Tolerance: ±0.016"/Linear Foot vs. Nominal
Squareness: ≤0.010"
Passes Requirements
ASTM F1914
Residual Indentation
Average <8%
Maximum – Any Sample ≤10%
Surpasses Requirements
ASTM F137
Flexibility
No cracks/breaks (1”/25.4mm Mandrel)
Surpasses Requirements
ASTM F2199
Dimensional Stability
≤0.020"/Linear Foot
Surpasses Requirements
ASTM F925
Chemical Resistance
No more than “Slight Change”
Surpasses Requirements
ASTM F1514
Resistance to Heat
Average ΔΕ < 8.0
Surpasses Requirements
ASTM F1515
Resistance to Light
Average ΔΕ < 8.0
Surpasses Requirements
STANDARDS – SAFETY & PERFORMANCE
Standard
Description
Requirements
Results
ASTM E648
Critical Radiant Flux (Radiant Panel)
Class I: ≥ 0.45 W/cm
2
Passes Requirements
1
ASTM E662
Smoke Density
Flaming & Non-Flaming ≤ 450
Passes Requirements
2
ASTM F963
Heavy Metals
Refer to Standard
Passes Requirements
ASTM D7823
Phthalates
Refer to CPSIA
3
Passes Requirements
ASTM D2047
Coefficient of Friction / Slip Resistance
N/A (No Official Requirements)
≥0.6 (Dry)
ASTM F970
Static Load
±0.005”, 250-Lbs. Load
Passes Requirements
SIM Test
Static Load Limit
Test to Limit (±0.005”)
≥1,000 psi
CERTIFICATIONS
Standard
Description
FloorScore
®
This product is FloorScore
®
Certified (Certificate #SCS-FS-02874) and has thus been found to comply with the volatile organic
compound emissions criteria of the California Section 01350 standard.
Notes
1) ASTM E648 - Critical Radiant Flux (Radiant Panel): Passes Requirements for Class I per International Building Code (IBC) 2018 & NFPA 101 Life Safety Code.
2) ASTM E662 - Smoke Density: 450 is the limit established by many state, county, and/or local building and/or fire codes but is not set as a limit for (resilient) flooring products
nationwide. Thus, Smoke Density requirements for flooring products may vary from jurisdiction to jurisdiction. Consult your building inspector / fire marshal to learn more.
3) ASTM D7823 - Phthalates: CPSIA = Consumer Product Safety Improvement Act.
*Ultra-Fresh is a registered trademark of Thomson Research Associates, Inc.