Product Info

Table Of Contents
Smart LTE Module Series
SC20 Hardware Design
SC20_Hardware_Design Confidential / Released
7-91
/ 122
Table 45: SC20-A Current Consumption
Parameter
Description
Conditions
Typ.
Unit
I
VBAT
OFF state
Power down
20
uA
GSM/GPRS supply current
Sleep USB disconnected)
@DRX=2
4.08
mA
Sleep (USB disconnected)
DRX=5
3.10
mA
Sleep (USB disconnected)
DRX=9
2.77
mA
WCDMA supply current
Sleep (USB disconnected)
DRX=6
3.86
mA
Sleep (USB disconnected)
DRX=7
2.90
mA
Sleep (USB disconnected)
DRX=8
2.55
mA
Sleep (USB disconnected)
DRX=9
2.43
mA
FDD-LTE supply current
Sleep (USB disconnected)
DRX=5
6.60
mA
Sleep (USB disconnected)
DRX=6
4.24
mA
Sleep (USB disconnected)
DRX=7
3.11
mA
Sleep (USB disconnected)
DRX=8
2.77
mA
GSM voice call
GSM850
PCL=5 @32.23dBm
254.60
mA
GSM850
PCL=12 @18.34dBm
136.30
mA
GSM850
PCL=19 @4.87dBm
111.30
mA
PCS1900
PC=L0 @29.14dBm
196.60
mA
PCS1900
PCL=7 @16.23dBm
158.40
mA
PCS1900
PCL=15 @0.62dBm
135.50
mA
WCDMA voice call
Band 1 (max power)
@23.24dBm
548.13
mA
Band 2 (max power)
575.70