User's Manual

Installation Manual 19
Battery Pack Maintenance
The supplied high-performance, smart Lithium-Ion battery
pack provides 7.2 VDC at 1450 mAH (minimum) capacity.
When fully discharged, the battery fully recharges within
three hours while installed in the terminal. An 80% charge
capacity is reached within one hour.
The terminal can be connected to an AC/DC power supply
indefinitely without causing damage to the battery.
In typical use, the life span of the battery pack exceeds
500 charge cycles, after which, operating time decreases
slowly.
The battery pack has a self-discharge rate. It loses
approximately 1% of its charge per day when not in use.
Replace the battery pack when the charge capacity is too
weak for normal operation.
Remove the battery pack from the terminal if you do not
intend to use your NURIT 8000 for an extended period of
time.
Caution
When using the Lipman-supplied AC/DC Power
Adapter, the Lithium-Ion battery pack must be
installed in the terminal.
Warning
Do not dispose of the battery pack in a fire.
Dispose of used batteries in accordance with
local recycling regulations. If you intend to
remove the battery pack, verify that the metal
contacts do not come in contact with any metal
objects.
Note
Extreme temperatures degrade the battery
performance. Do not store the battery pack in
temperatures below -20°C (4°F) or above 60°C
(140°F).