Specifications

Performing Downloads
Application Downloads 75
Preparing the Omni 3200 Terminal
To prepare the Omni 3200 terminal for a ZONTALK application
download by telephone, the following requirements must be met:
The internal modem of the Omni 3200 terminal must be
connected to a dial-up telephone line using a direct (Telco) or
pass-through (Telset) connection.
The following keyed record variables are required by the
ZONTALK download program, and should be stored in the
terminal’s CONFIG.SYS file:
Note: If the required ZONTALK variables (*ZP, *ZT, *ZA) are not
stored in CONFIG.SYS when you initiate the application download, a
prompt will appear on the terminal display asking you to enter each
missing value.
Complete dial-up telephone number of the remote download
computer, including access numbers and prefixes (protected
record key *ZP).
Omni 3200 terminal ID (protected record key *ZT).
This ZONTALK terminal ID is different than the permanent
terminal ID (PTID) that is set at the factory. The *ZT variable
is usually assigned prior to deployment of an Omni 3200
terminal to an end-user site, and can be modified in
CONFIG.SYS using the keyed file editor. The terminal ID is
a maximum 10-character alphanumeric value.
Application program ID (protected record key *ZA).
The application ID is usually assigned prior to deployment of
an Omni 3200 terminal to an end-user site, and can be
modified in CONFIG.SYS using the keyed file editor. The
application ID is a maximum 21-character alphanumeric
value.
O3200 RM Book.book Page 75 Thursday, April 29, 1999 3:48 PM