Specifications
Omni 3200 Reference Manual
82 Application Downloads
Starting a Terminal-to-Terminal Upload Procedure
Before you start the procedure described in Table 22:
• Verify that the application software and all configuration settings
on the sending terminal are those you wish to upload to the
receiving terminal.
• Verify that the firmware version on both Omni 3200 terminals is
identical and that the SRAM size of the receiving terminal is at
least the same size as that of the sending terminal.
Note: The following procedure requires that you perform actions on
both the sending and receiving terminal. For this reason, information
in the Display and Action column is presented twice, and steps are
numbered accordingly as 1a, 1b, 2a, 2b, and so on.
Caution: Any existing application, and all records stored on the
receiving terminal, protected and non-protected, will be overwritten!
Table 22 Terminal-to-Terminal Application Upload
Display Action
1a. Sending Terminal:
SYSTEM=
(Firmware ID)
Press [*] on the sending terminal to initiate the special
full application upload.
1b. Receiving Terminal:
SYSTEM=
(Firmware ID)
Press [#] on the receiving terminal to receive the upload
from the sending terminal.
2a. Sending terminal:
UNIT SEND
(then)
FFFFFF
(Memory block address)
The
UNIT SEND
prompt is displayed on the sending
terminal until the upload begins.
So that you can monitor the progress of the upload, a
continuously updating 6-digit hexadecimal number is
displayed and updated, indicating the address of the
memory block currently being uploaded.
O3200 RM Book.book Page 82 Thursday, April 29, 1999 3:48 PM