SETUP
Grounding the Reader
UX300 M
ANUAL CARD READER INSTALLATION GUIDE 23
Grounding the
Reader
When the reader is connected to one of the UX-series PIN pads, it is important to
ground your units.
To ground the reader
1 Remove a nut, exposing a stud from the back of the PIN pad unit (do not use
the one from the cable retainer). See (A) in .Figure 11.
2 Attach the grounding cable to the UX300 (P/N WIR159-302-01-A) and the
grounding cable to a ground installation. See (A) in Figure 11.
3 Tighten the nut, to secure the PIN pad.
4 Remove a nut, exposing a stud from the back of the UX300 unit.
5 On the UX300 unit stud, attach the other end of the grounding cable from the
PIN pad (P/N WIR159-302-01-A) and the grounding cable to a ground
installation (P/N WIR159-302-02-A). See (B) in Figure 11.
6 Tighten the nut, to secure the UX300 device.
NOTE
For cable use and ordering information, see Accessories and Documentation.
NOTE
To tighten the nuts, using a recommended tightening torque of 7.0 kgfcm.