User's Manual

UX301 INSTALLATION GUIDE 27
CHAPTER 3
Specifications
This chapter discusses power requirements, dimensions, and other specifications
of the UX301 card reader.
Unit Power
Requirements
Operation voltage: 8 to 43V DC, 24V DC for Printer use
Idle Power: 2W
Typical Power: 3W (CTLS read), 4W (UX100 display heater), 0.5W (UX100/
110), 5W (RS232-vout)
Sleep Mode: TBD.
Temperature
Operating temperature:
-30°C to 70°C (-22°F to 158°F) Standard unit
Storage temperature: -25°C to 70°C (-13°F to 158°F)
Power Supply rated for indoor use only: 12V DC 3.3A, operating temperature
0°C to 40°C (32°F to 104°F)
Power Supply rated for outdoor use: 24V, DC 3.75A up to 40°C (DC 2.5A up to
60°C), operating temperature -25°C to 60°C
Relative humidity: 5% to 90% RH non-condensing
External Dimensions
Height: 67 mm (2.64 in)
Width: 97 mm (3.82 in)
Depth 102 mm (4.02 in)
Memory
128 MB DDRAM
256 MB NAND-Flash
Magnetic Stripe
Card
Triple-track
NOTE
If this device is to be used in the Nordic countries, or in any environment where
the temperature range exceeds the product’s operating temperature, it is the
responsibility of the integrators to ensure that the ambient environment is
controlled in such a way to ensure that the product operates within the specified
temperature range.