Specifications

SYSTEM MESSAGES
Information Messages
VX 520 R
EFERENCE GUIDE 167
INTERNAL PIN PAD DIAGNOSTICS INFORMATION
INTERNAL PIN PAD
MEMORY TEST PASSED
IPP8 EMUL01A 07/05 OD
SN: 246021114A009999
BAUD: 1200 RESET F3
MODE: VISA
EXIT F4
After an internal PIN pad diagnostic session, the
firmware version and download date, IPP serial
number, baud rate, and mode are displayed.
KEYBOARD DIAGNOSTICS INFORMATION
VERIX TERMINAL MGR KBD
TEST
KEYCODE nn
This screen displays the hexadecimal ASCII keycode
for each key you press during a keyboard diagnostics
session. The value displayed corresponds to the
actual key pressed. Other values assigned to keys are
software dependent.
MAGNETIC CARD DIAGNOSTICS INFORMATION
VERIX TERMINAL MGR
TRK 1:VALID DATA
TRK 2:VALID DATA
TRK 3:VALID DATA
When you invoke a local terminal manager diagnostic
test of the magnetic stripe card reader, status
information appears for the data tracks (TRK1, TRK2,
and TRK3) on the card.
A successful test displays
VALID DATA for each track
that reads valid data. An error generates one of the
following error messages for each track with an error:
NO DATA
NO START
NO END
LRC ERR
PARITY ERR
REVERSE END
For more information about magnetic card error
messages, refer to the Verix eVo OS Programmers
Manual (VPN DOC00301).
MEMORY INFORMATION
MEMORY USAGE
RAM FILES nnnn
INUSE nnnn
AVAIL nnnn
FLASH FILES nnnn
INUSE nnnn
AVAIL nnnn
This screen displays how much RAM and flash
memory is used and how much is available.
INUSE - Closest estimate of used memory (in KB).
AVAIL - Lowest number of free memory (in KB).
Table 24 Information Messages
Display Action