User's Manual
Table Of Contents
- Vx680
- Contents
- Preface
- Terminal Overview
- Terminal Setup
- Selecting Terminal Location
- Unpacking the Shipping Carton
- Examining Terminal Features
- Examining Connection Ports
- Establishing Telephone Line Connections
- Installing the Paper Roll
- Installing/ Replacing MSAM Cards
- Installing/ Replacing SIM Card (GSM/ GPRS Models Only)
- Using the Smart Battery
- Battery Behavior (No Power Cable)
- Installing the Smart Battery
- Connecting the Terminal Power Pack
- Charging the Smart Battery
- Using the Base Station
- Placing the Terminal Onto the Base Station
- Attaching the USB Dongles to the Base Station
- Charging the Spare Battery on the Base Station
- Conducting Wireless Transactions
- Conducting Smart Card Transactions
- Conducting Bluetooth® Transactions
- Using the Magnetic Card Reader
- Specifications
- Maintenance
- VeriFone Service and Support
- Troubleshooting Guidelines
- Terminal Does Not Start
- Terminal Display Does not Show Correct/ Readable Info
- Terminal is Unable to Go Online and Displays Connection Failure (for Bluetooth® variant)
- Smart Battery Will Not Charge
- Spare Battery in Base Station Will Not Charge
- Blank Display
- Terminal Does Not Dial Out
- Printer Does Not Print
- Printer Paper Jam
- Keypad Does Not Respond
- Transactions Fail To Process
- Index
- Contact VeriFone
TERMINAL SETUP
Using the Smart Battery
32 V
X
680 INSTALLATION GUIDE
V
E
R
I
F
O
N
E
C
O
N
F
I
D
E
N
T
IA
L
R
E
V
I
S
I
O
N
A
.
3
Using the Smart
Battery
The V
x
680 terminal uses a Li-ion smart battery (see Accessories and
Documentation for ordering information). The internal logic of the smart battery
prevents both overcharging and undercharging (a fault condition in which the
battery level goes well below the minimum acceptable charge and the battery
becomes unusable).
Smart Battery
Features
The following are features of the smart battery:
• Two Li-ion cells
• A fuel gauge module that:
• monitors state of charge (voltage and percentage of capacity),
• communicates with the terminal (charge parameters and status),
• determines full charge capacity (on charge cycle and uninterrupted
discharge cycle), and
• automatically shuts down when cell voltage is extremely low.
• A safety circuit that:
• prevents cell damage from overcharge, over-discharge, or overheating,
and
• activates when the battery is left in an unused terminal for extended
periods.
NOTE
The V
x
680 terminal will operate on battery power or on power pack power. The
smart battery charger in the terminal will be active whenever the power pack is
connected.
NOTE
• Lithium-ion batteries are not affected by shallow charging. Furthermore, when
the terminal has no external power source or smart battery, the coin cell
battery provides power to the security circuit.
• Uninstalling the battery and unplugging the terminal power pack reduce the
life of the coin cell battery, which does not recharge and must be replaced if
drained.
• Conserve battery power by turning the V
x
680 terminal off when not in use. If
the terminal is not to be used for an extended period of time, keep the Lithium-
ion battery inserted in the terminal, and power up the terminal periodically to
check the battery charge. Do not let the battery charge fall below 10% for
extended periods of time as this may permanently diminish the battery
capacity. Recharge the battery by attaching the power cable to the terminal
and plugging the power pack into a wall outlet.