Instructions Owner manual

Veris Technologies
Pub. #OM 1CM02-1
5
5) If the readings vary greatly (more than one whole number) contact our service
department.
6) Once the test is complete, remove the test load and reinstall the implement signal cable.
Test Load
Note: It is advisable to conduct this test as a routine check to ensure that you are obtaining
reliable data.
Note: This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at their own expense.
Changes and modifications not expressly approved by Veris Technologies could void the user’s
authority to operate the Veris 3100.
Implement
If the unit is delivered by commercial truck, the tongue must be installed prior to use. To do so, please
take precautions to ensure that the framework is properly supported to ensure safety.
1) Remove bands that attach tongue and framework to shipping pallet.
2) Use a forklift or small loader to raise front portion of tongue into level position and properly
support with a sawhorse or other support of your choice.