User's Manual

3.3.4 Import 5GmmW gNBcalibrations files
Download the calibration files “mdm1m9kefs1”, “mdm1m9kefs2” and“tfcs_nv” which
are formerly backuped from PC to the gNB, under the directory
“/home/tetra/bootdevice/by-name”
Check the calibration files status
[Precautions]
After importing the calibration file, in order to avoid the error caused by the
synchronization failure between the wcp tool and the operating system file, you need to
double-click the iconbutton on the right window of the wcp tool. The specific
operation is shown in the above figure. At the same time, check and confirm the import of
calibration files on 5gmmw GNB, and execute the sync command. The specific operation
is shown in the figure below.
root@localhost:~#ls /home/tetra/bootdevice/by-name/ -pla
root@localhost:~# sync
3.3.5 Restart 5GmmW gNB
root@localhost:~#reboot
When the command prompt is showninput user name/password as root/root