Instruction Manual

NOTE Changes from one scaling factor to another will take
place after a waveform cycle has been completed. Do
not worry about a possible delay after switching at
slower tempos - this is intended.
Internal MIDI-CLOCK
The PerFourMer MKII can also generate an internal clock to synchronize the
LFOs. Its tempo can be adjusted using a TAP function.
To use the internal clock as LFO clock-reference, follow these steps:
1. Press the EDIT-button.
2. Select parameter 9: INTERNAL MIDI CLOCK using the SELECT/SEQ
control.
3. Press TRIG to enable the internal clock-synchronization. The corre-
sponding red LEDs above the TRIG-buttons will display the synchro-
nization status. This is a global parameter, valid for all synthesizer
channels.
4. Exit edit-mode by pressing the EDIT-button.
To change the tempo for the internal clock signal, follow these steps:
1. Press the EDIT-button.
2. Select parameter 10: MIDI CLOCK TEMPO using the SELECT/SEQ
control.
3. Press any of the four TRIG buttons to TAP the tempo. The TRIG LEDs
will be blinking with the current tempo. The new deļ¬ned tempo will be
set after four taps.
4. Exit edit-mode by pressing the EDIT-button.
Owner's Manual VERMONA PERfourMER MKII
- 19 -