INSTALLER/CONSUMER SAFETY INFORMATION PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. Direct Vent / Natural Vent Gas Heater Models: 2465, 2466 FOR YOUR SAFETY Installation and service must be performed by a qualified installer, service agency or the gas supplier. WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance.
Dutchwest Direct Vent / Natural Vent Gas Heater Table of Contents PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Dutchwest stove. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. 2 Installation & Operating Instructions .....................................................................
Dutchwest Direct Vent / Natural Vent Gas Heater General Information The Dutchwest Direct Vent/Natural Vent Room Heater, Model Nos. 3070, 3071, 3072 and 3073, is a vented gas appliance listed to the ANSI standard Z21.88b-2001 and CSA-2.33b-2001 for Vented Room Heaters, and CSA 2.17M91, Gas-Fired Appliances For Use at High Altitudes. The installation of the Dutchwest Direct Vent/Natural Vent Room Heater must conform with local codes, or in the absence of local codes, with National Fuel Gas Code, ANSI Z223.
Dutchwest Direct Vent / Natural Vent Gas Heater Dutchwest Direct Vent / Natural Vent Dimensions Refer to Page 6 for Flue Collar Centerline Dimensions 6���" (172mm) CL Valve Inlet 24���" (622mm) 28���" (721mm) C Valve 4���" L Inlet (111mm) 12���" (318mm) 23" (584mm) 17" (419mm) Fig. 1 Dutchwest dimensions. 1935 Dutchwest Attention DV/NV dimensions The Dutchwest stove is shipped from the factory as a Direct Vent Gas Heater. This heater may be convert5/15/03 ed into a Natural Vent unit in the field.
Dutchwest Direct Vent / Natural Vent Gas Heater Installation Requirements The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest edition. (EXCEPTION: Do not derate this appliance for altitude. Maintain the manifold pressure at 3.5” w.c. for Natural Gas, and 10” w.c. for Propane). Direct Vent System Only A In Canada, installation must be in accordance with the current CSA B-149.
Dutchwest Direct Vent / Natural Vent Gas Heater Parallel Installation: Minimum Clearance and Flue Centerline, Direct Vent and Natural Vent Wall Centerline from Floor C L C A D A C L B Stove Clearances Pipe Centerlines A: 4” (102 mm) B: 4” (102 mm) C: 15¹⁄₂” (395 mm) D: 9” (229 mm) ST128b ST128c ST131c A Fig. 3 Parallel installation, minimum back and side clearStardance ances and flue centerlines.
Dutchwest Direct Vent / Natural Vent Gas Heater Horizontal Termination Direct Vent ONLY Gas Specifications Model 2465 2466 Fuel Nat Prop Gas Control Millivolt Millivolt Max. Input BTU/h 28,000 28,000 Min. Input BTU/h 20,000 19,000 Weight: Fully assembled; 202 lbs. Gas Inlet and Manifold Pressures Inlet Minimum Inlet Maximum Manifold Pressure Natural 5.5” w.c. 14.0” w.c. 3.5” w.c. LP (Propane) 11.0” w.c. 14.0” w.c. 10.0” w.c.
Dutchwest Direct Vent / Natural Vent Gas Heater Vent Termination Clearances Vertical Termination - Direct Vent ONLY A vertical vent system must terminate no less than 8’ (2.44m) and no more than 40’ (12m) above the appliance flue collar. A 2¹⁄₄” restrictor plate (supplied) must be used where specified in all vertically terminated vent systems. (Fig. 8) NOTE: The restrictor plate supplied with the vertical termination should be discarded. Install restrictor plate supplied with stove directly at stove outlet.
Dutchwest Direct Vent / Natural Vent Gas Heater Venting Termination Clearances Your stove is approved to be vented either through the side wall, or vertical through the roof. • • • • • This unit does not require any opening for inspection of vent pipe. Only CFM Corporation and Simpson DuraVent venting components specifically approved and labelled for this stove may be used. Minimum clearances between vent pipes and combustible materials is one (1”) inch (25 mm), except where stated otherwise.
Dutchwest Direct Vent / Natural Vent Gas Heater General Venting Information - Termination Location INSIDE CORNER DETAIL G V H A N N D L V E C B V F B ����� ������ Ope B V Operable rable V B B B J X X AIR SUPPLY INLET M I A CFM145a V VENT TERMINATION V V Fixed Closed C = Clearance to permanently closed window D = Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (610mm) from the center line of the terminal E = Clearance to
Dutchwest Direct Vent / Natural Vent Gas Heater Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Alcove Applications* Outside Corner G= Combustible 6" (152 mm) G F= Combustible 6" (152 mm) Noncombustible 2" (51 mm) V Noncombustible 2" (51 mm) V C V E O F Balcony with perpendicular side wall Balcony with no side wall D C E = Min. 6” (152 mm) for non-vinyl sidewalls Min. 12” (305 mm) for vinyl sidewalls O = 8’ (2.4 m) Min.
Dutchwest Direct Vent / Natural Vent Gas Heater Venting Requirements and Options Direct Vent ONLY Approved Vent System Components The Dutchwest Heater must be vented to the outdoors through an adjacent exterior wall or through the roof. The venting system must be comprised of the appropriate listed venting components specified on this page. These parts are available from DuraVent Corporation or your CFM Corporation Dealer. Refer to Figure 4 for dimensions relevant to the standard minimum-vent kits.
Dutchwest Direct Vent / Natural Vent Gas Heater • Remove retaining nut from shaft of rheostat. (if Install the Optional Fan If you are installing the optional convection Fan Kit #2767 (FK26), continue here. If you are not installing a Fan Kit, go to Page 14, Venting System Assembly. 1. The fan kit includes a Blower Assembly and a Rheostat Assembly, connected by a cable. (Fig. 12) The Blower Assembly mounts to the bottom rear of the stove, and the Rheostat mounts to the valve coverplate.
Dutchwest Direct Vent / Natural Vent Gas Heater Venting System Assembly - Direct Vent General Information The Dutchwest is approved for installation only with the vent components listed on Page 12. Follow the vent component instructions exactly. For U.S. installations: The venting system must conform with local codes and/or the current National Fuel Gas Code, ANSI Z223.1/NFPA 54. 5. Install the Outer Adapter Pipe. Apply a 1/4” bead of cement around the inside wall of the pipe, about 1” from the end.
Dutchwest Direct Vent / Natural Vent Gas Heater Install the Vent Adapter Pipe Side Wall Termination Assembly (Simpson Dura-Vent Components) 1. Install the Restrictor Plate. Consult the ‘Vent Run Specifications’ on Page 8 to determine whether the restrictor plate is needed. If so, put the restrictor plate in place within the inner flue collar. (Fig. 16) 2. Discard the inner starter pipe shipped with the logset. Using the starter pipe assembly listed on Page 7, slide the inner section out to allow access.
Dutchwest Direct Vent / Natural Vent Gas Heater For DuraVent pipe only: Install vent pipe by aligning the locking system together, sliding the pipes together and twisting clockwise. • Install 90° elbow. Twist lock as before. • Slide the wall plate over horizontal run before attaching the horizontal run to the elbow. Fasten wall plate to wall. 4.
Dutchwest Direct Vent / Natural Vent Gas Heater Vent Termination Below Grade Recessed Wall Install Snorkel Kit #7FSDVSKS when it is not possible to meet the required vent termination clearances of 12” (305mm) above grade level. The snorkel kit will allow installation depth of down to 7” (178mm) below grade level. The seven inches is measured from the center of the horizontal vent pipe as it penetrates the wall.
Dutchwest Direct Vent / Natural Vent Gas Heater 8. Install appropriate pipe sections until the vent run reaches above the flashing. The enlarged ends of the vent sections always face downward. 9. Install the storm collar and seal around the joints. (Fig. 31) 10. Add additional vent lengths to achieve the proper overall height. 11. Apply cement to the inner and outer termination collars and install the terminal cap.
Dutchwest Direct Vent / Natural Vent Gas Heater Attach the first section of venting to the draft hood. Depending on the length of the individual venting sections and the lengths of the decorative pipe (if installed), you may need to slip the decorative pipe over the venting sections before attaching upper sections to lower ones. The sections of decorative pipe should be oriented with their seams (if any) toward the wall; sections usually do not need to be fastened at each joint, other than slip sections.
Dutchwest Direct Vent / Natural Vent Gas Heater In the U.S.; Gas connection should be made in accordance with current National Fuel Gas Code, ANSI Z223.1/NFPA 54. Since some municipalities have additional local codes, be sure to consult your local authority. In Canada; consult the local authority and CSA-B149.1 installation code. Always check for gas leaks with a mild soap and water solution. Do not use an open flame for leak testing.
Dutchwest Direct Vent / Natural Vent Gas Heater 8. The air shutter is located on the bottom of the burner to the left. (Fig. 37) Unfasten the two nuts holding the shutter in place. The shutter may be adjusted between the factory adjusted 1/2” to fully open. Reassemble the shutter to allow the rear injector air inlet to close from the minimum 1/2” opening to fully open. (Fig. 39) You may have to try more than once to find the correct air shutter opening for best results depending on your altitude.
Dutchwest Direct Vent / Natural Vent Gas Heater Thermostat Connection (optional) Use only a thermostat rated for 500 millivolts. Check the table below for the appropriate gauge thermostat wire to use for the length of lead required in your installation. Thermostat Wire / Gauge 18 16 14 3/8” Locking Nut Maximum Run 20 feet 20 - 40 feet up to 60 feet 1. Install the wall thermostat in the desired location and run the wires to the stove location. Terminate these leads with 1/4” female connectors. 2.
Dutchwest Direct Vent / Natural Vent Gas Heater Operation Flame & Temperature Adjustment Read these instructions carefully and familiarize yourself with the burner controls. Locate the pilot assembly, Figure 45. Follow the lighting instructions on Page 25 exactly. For stoves equipped with HI/LO valves, flame adjustment is accomplished by rotating the HI/LO adjustment knob located near the center of the gas control valve. (Fig.
Dutchwest Direct Vent / Natural Vent Gas Heater Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manually. When lighting the pilot follow these instructions exactly. B. BEFORE LIGHTING smell all around the heater area for gas.
Dutchwest Direct Vent / Natural Vent Gas Heater Troubleshooting / Honeywell #8420 Gas Control System NOTE: Before troubleshooting the gas control system, be sure the external gas shutoff is in the “ON” position. WARNING: REMOVE THE GLASS PANEL BEFORE PERFORMING ANY GAS CONTROL SERVICE WORK. SYMPTOM POSSIBLE CAUSES 1. Spark ignitor will not A. Defective or misaligned eleclight trode at the pilot B. Defective ignitor (push button) 2.
Dutchwest Direct Vent / Natural Vent Gas Heater Fuel Conversion Instructions OFF O H PILOT ADJ ON L I PIL OT WARNING! This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life.
Dutchwest Direct Vent / Natural Vent Gas Heater A Pilot Hood B Pilot Bracket C CO105a Fig. 53 Remove pilot hood. FP OF IL OT Allen Wrench O Index Tab CO105a gas conversion Pilot 1/28/00 djt FC107 Fig. 51 Remove mounting screws, pressure regulator tower and spring and diaphragm assembly. Snap Ring E CO106a FC107 SIT820 valve conversion 10/03 Fig. 54 Remove pilot orifice. IL FP OF OT Index Marks O D CO106a DV360/580 Gas Conversion Pilot2 1/28/00 djt Pilot Pilot Bracket CO105 Fig.
Dutchwest Direct Vent / Natural Vent Gas Heater 21. Replace burner. Slide the burner in at an angle with left side lower than the right side. Slide the left side onto the injectors, making sure the burner leg remains at a 90° angle to the base. Lower the right hand side down in to place. Make sure the burner is as far left as possible and the injector shoulders are inside the burner. NOTE: It is very critical to keep the left burner leg, which holds the injectors, at a 90° angle to the base. (Fig.
Dutchwest Direct Vent / Natural Vent Gas Heater Maintenance Your Dutchwest Gas Heater will provide years of service with minimal upkeep. The following procedures will help ensure that your stove continues to function properly. Annual System Inspection Have the entire heater and venting system inspected annually by a qualified gas technician. Replace any worn or broken parts. Logset and Burner / Cleaning and Inspection Cleanliness is critical to the proper function of the heater.
Dutchwest Direct Vent / Natural Vent Gas Heater Gasket Replacement Check the Gas Flame Regularly The Dutchwest Gas Heater uses a ‘tadpole’ type gasket to seal between the glass panel and the frame. In time, this gasket can become brittle and compressed and should be replaced. New gasket is available from your dealer. To ensure that the stove is operating properly, check the flames periodically to confirms they match Figure 61.
Dutchwest Direct Vent / Natural Vent Gas Heater Wiring Diagrams OFF On/Off Switch Wiring Thermopile Black BL Millivolt Gas Valve TP K GRN BL K BLK ST124b Thermostat FAN JUNCTION BOX Thermostat (Optional) Strain Relief Thermopile Black Optional Thermostat (Optional) Wiring TH Chassis Ground Black TH TP BLK WHT TP/TH TP/TH FAN POWER CORD ON St124b on/off/switch wiring 1/11/00Blackdjt ON / OFF Rheostat Millivolt Gas Valve ST124c Snapstat Fig.
Dutchwest Direct Vent / Natural Vent Gas Heater 2 1 7 3 6 4 1a 1c 5 1b 13a,b 12 10 17 11 18 8 15b LO O H PILOT ADJ ON L I 14 15a T OFF PI 19 22 30 20 23 16a,b, c,d 24 21 26 25 29 9 27 28 32 30 33 34 37a,b 31 36 NT ME CE 35 38 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
Dutchwest Direct Vent / Natural Vent Gas Heater Dutchwest Direct Vent / Natural Vent Gas Heater Models 2465, 2466 (continued) Ref. 10. 11. 12. 13a. 13b. 14. 15a. 15b. 16a. 16b. 16c. 16d. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37a. 37b. 38. 39. Description Glass, DV25 Glass Frame Assembly - SDV30 Gasket, Glass - Med.
Dutchwest Direct Vent / Natural Vent Gas Heater Optional Accessories Fan Kits FK26 Fan The FK26 fan helps distribute heated air from within the firebox out into the room. The fan is controlled by a snapstat that turns power on and off as the firebox temperature rises above and falls below a preset temperature. A rheostat provides for variable fan speeds. Specifications Remote Controls The remote control allows you to turn the heater on or off from anywhere in the room. Refer to Page 32 for wiring diagrams.
Dutchwest Direct Vent / Natural Vent Gas Heater LIMITED LIFETIME WARRANTY PRODUCT COVERED BY THIS WARRANTY All Dutchwest gas stoves equipped with an Insta-Flame Ceramic Burner. BASIC WARRANTY CFM Corporation Company (hereinafter referred to collectively as the Company) warrants that your new Dutchwest Gas Fireplace/Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions and limitations.
Efficiency Ratings Model 2465 2466 EnerGuide Ratings Fireplace Efficiency (%) 63.0 63.0 CFM Corporation 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www.cfmcorp.