INSTALLER / CONSUMER SAFETY INFORMATION PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE. WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. Dutchwest Natural Vent Gas Heater Models: 2467, 2468 FOR YOUR SAFETY Installation and service must be performed by a qualified installer, service agency or the gas suppler. WHAT TO DO IF YOU SMELL GAS: • Do not try to light any appliance.
Dutchwest Natural Vent Gas Heater Table of Contents PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Dutchwest stove. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Installation & Operating Instructions .......................................................................................
Dutchwest Natural Vent Gas Heater Installation & Operating Instructions The Dutchwest Natural Vent Room Heater, Model Nos. 2467 and 2468, is a vented gas appliance listed to the ANSI standard Z21.88b-2001 and CSA-2.33b-2001 for Vented Room Heaters, and CSA 2.17-M91, Gas-Fired Appliances For Use at High Altitudes. The installation of the Dutchwest Natural Vent Room Heater must conform with local codes, or in the absence of local codes, with National Fuel Gas Code, ANSI Z223.
Dutchwest Natural Vent Gas Heater Dutchwest Natural Vent Gas Heater Dimensions See Page 5 for Flue Collar Centerline Dimensions. 6���" (172 mm) CL Valve Inlet 24���" (622 mm) 28���" (721 mm) C Valve 4���" L Inlet (111 mm) 12���" (318 mm) 23" (584 mm) 17" (419 mm) Fig. 1 Dutchwest dimensions.
Dutchwest Natural Vent Gas Heater Ceiling Clearances Clearance Requirements Minimum Clearances to Combustible Materials 45" (1140mm) Measure side clearances as shown in Figures 2 through 5 from the outer edge of the cast iron stove top. Measure rear clearances from the outermost surface of the sheet metal rear skirt. 72" (1829mm) The Dutchwest heater is approved for installation into an alcove constructed of combustible materials to the dimensions and clearances shown in Figure 5.
Dutchwest Natural Vent Gas Heater Gas Specifications Model Fuel Gas Control Max. Input BTU/h 2467 2468 Nat Prop Millivolt Millivolt 28,000 28,000 Venting Requirements and Options Min. Input BTU/h 20,000 19,000 Weight: Fully assembled 350 lbs. Gas Inlet and Manifold Pressures Inlet Minimum Inlet Maximum Manifold Pressure Natural 5.5” w.c. 14” w.c. 3.5” w.c. LP (Propane) 11” w.c. 14” w.c. 10” w.c. Dutchwest Natural Vent Certified to: ANSI Z21.86b-2001 / CSA Z2.
Dutchwest Natural Vent Gas Heater Passing Through a Combustible Wall or Ceiling Venting Requirements Complete the venting system installation according to the manufacturer’s instructions. Air Space as Required by Code Joists Ceiling Support 36 Vertical Run (in feet) (Measured from top of the unit before any elbow) An approved pass-through device is always required when a vent passes through a combustible wall or ceiling.
Dutchwest Natural Vent Gas Heater Install the Optional Fan 1. The fan kit includes a blower assembly and a rheostat assembly, connected by a cable. The blower assembly mounts to the bottom rear of the stove, and the rheostat mounts to the left side of the valve. The assembly includes a ‘snapstat’ which automatically turns the fan ON (or OFF) above (or below) approximately 109°F. The rheostat also provides a range of fan speed settings from Off (which overrides the snapstat function) to High.
Dutchwest Natural Vent Gas Heater Venting System Assembly Snapstat Left Air Duct ST671 Fig. 12 Install the snapstat and connect the extension wire terminals. View is with top removed, however, access is available through the rear when installing fan before gas line connection. 9. After sliding the firebox in place, the rheostat control switch attaches to the left side of the valve bracket at the front of the stove. (Fig. 13) • Remove the plug from the rheostat bracket.
Dutchwest Natural Vent Gas Heater Attach the first section of venting to the B-vent adapter. Depending on the length of the individual venting sections and the lengths of the decorative pipe, you may need to slip the decorative pipe over the venting sections before attaching upper sections to lower ones. The sections of decorative pipe should be oriented with their seams (if any) toward the wall; sections usually do not need to be fastened at each joint, other than slip sections.
Dutchwest Natural Vent Gas Heater Burner Information PILOT ADJ TPTH The appliance must only use the gas specified on the rating plate, unless converted using a CFM Corporation Fuel Conversion Kit. Refer to Page 23 for the correct Fuel Conversion Kit for your model. Conversion instructions are provided with each kit and beginning on Page 16 in this manual. TP THIS APPLIANCE SHOULD BE CONNECTED TO THE GAS SUPPLY ONLY BY A QUALIFIED GAS SERVICE TECHNICIAN. FOLLOW ALL LOCAL CODES.
Dutchwest Natural Vent Gas Heater Install the Stove Front Left Log Right Log Insert the handle stub into the hole in the front casting. Fasten in place with the 3/8” locking nut provided. (Fig. 23) The front attaches to the stove by four steel tabs that engage with corresponding cast ribs onto the sides and bottom of the stove body. Position the front about 3” down from stove top and lift the plate to engage the upper tabs behind the adjacent ribs on the sides. (Fig.
Dutchwest Natural Vent Gas Heater Operation Your First Fire Read these instructions carefully and familiarize yourself with the burner controls. Locate the pilot assembly, Figure 25. Follow the lighting instructions on Page 14 exactly. During the first fire, it is not unusual to smell some odor associated with new logs, paint and metal being heated. Odors should dissipate within an hour or so, however, you can open a window to provide fresh air to alleviate the condition.
Dutchwest Natural Vent Gas Heater Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manually. When lighting the pilot follow these instructions exactly. B. BEFORE LIGHTING smell all around the heater area for gas.
Dutchwest Natural Vent Gas Heater Troubleshooting / Honeywell #8420 Gas Control System NOTE: Before troubleshooting the gas control system, be sure the external gas shutoff is in the “ON” position. WARNING: REMOVE THE GLASS PANEL BEFORE PERFORMING ANY GAS CONTROL SERVICE WORK. SYMPTOM 1. Spark ignitor will not light POSSIBLE CAUSES A. Defective or misaligned electrode at the pilot B. Defective ignitor (push button) 2. Pilot will not stay lit after carefully following the lighting instructions A.
Dutchwest Natural Vent Gas Heater Fuel Conversion Instructions WARNING! This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life.
Dutchwest Natural Vent Gas Heater • Remove pilot orifice with allen wrench. (Fig. 32) • Install the conversion orifice. • Reinstall pilot hood. Be sure to align hood with 1/8" Air Shutter (LP Position) index tab. 3/8" Pilot Hood Configuration for Stove with Serial #’s up to #5483 Pilot Bracket CO105a Index Tab ST726 SNV Leg Left Burner air shutter lp gas position Injector Orifices 8/23/02 djt Allen Wrench CO105a gas conversion Pilot 1/28/00 djt CO106a 90° ST353a Fig.
Dutchwest Natural Vent Gas Heater Table 2. Injector Orifice Size Matrix 18 Kit # 000-5021 Conversion to Natural Gas Front Part # Rear Part # #54 / .055” 20000130 #44 / .086” 30000334 Input (BTU/h) Minimum Maximum 19,000 28,000 Air Shutter Setting Fully Closed Kit # 000-5022 Conversion to LP Front Part # Rear Part # #69 / .029” 30000513 #54 / .
Dutchwest Natural Vent Gas Heater Maintenance Your Dutchwest Gas Heater will provide years of service with minimal upkeep. The following procedures will help ensure that your stove continues to function properly. Annual System Inspection Have the entire heater and venting system inspected annually by a qualified gas technician. Replace any worn or broken parts. Logset and Burner / Cleaning and Inspection Cleanliness is critical to the proper function of the heater.
Dutchwest Natural Vent Gas Heater Inspect the Vent System Annually Have the vent system inspected annually by a qualified technician. Shut off the main gas supply before inspecting the system. Both the inner exhaust pipe and the outer combustion supply pipe must be checked to confirm that they are unblocked and in good condition. Check the Gas Flame Regularly ST582 Fig. 37 Release the latches to release the glass frame.
Dutchwest Natural Vent Gas Heater Wiring Diagrams ON OFF Thermopile Black On/Off Switch Wiring TP/TH BL Chassis Ground TP Black TH FAN POWER CORD Optional Thermostat Wiring BL K BLK Thermostat (Optional) FAN JUNCTION BO X St124b on/off/switch wiring 1/11/00 djt Thermopile Black TP/TH Millivolt Gas Valve K GRN ST124b Thermostat (Optional) BLK WHT Strain Relief ON / OFF Rheostat TP Black TH Snapstat ST124c LK WHT BLK B Fig. 40 On/off switch and optional thermostat circuit.
Dutchwest Natural Vent Gas Heater 4 2 1 8 9 5 1a 3 1c 14a,b I OH L T O LOFF PI PILOT ADJ 12 13 ON 11 10 7 6 1b 17 16 18 19 22a,b,c,d 26 24 15a,b 27 25 21 30a,b 29 28 23a,b 34 32 31 20 35 33 39 37 38 2008 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. Dutchwest Natural Vent Gas Heater Models 2467, 2468 Ref. 1. 1a. 1b. 1c. 2. 3. 4. 5. 6. 7.
Dutchwest Natural Vent Gas Heater Dutchwest Natural Vent Gas Heater (continued) Models 2467, 2468 Ref. 8. 9. 10. 11. 12. 13. 14a. 14b. 15a. 15b. 16. 17. 18. 19. 20. 21. 22a. 22b. 22c. 22d. 23a. 23b. 24. 25. 26. 27. 28. 29. 30a. 30b. 31. 32. 33. 34. 35. 37. 38. 39. Description End, Rt - DW Gas End, Lt - DW Gas Gasket, Glass Med.
Dutchwest Natural Vent Gas Heater Optional Accessories Available Fan Kits FK26 Fan The FK26 fan kit helps distribute heated air from within the firebox out into the room.. The fan is controlled by a snapstat that turns power on and off as the firebox temperature rises above and falls below a preset temperature. A rheostat provides for variable fan speeds. Specifications 115 Volt / 60Hz / .
Dutchwest Natural Vent Gas Heater 30002008 25
Dutchwest Natural Vent Gas Heater 26 30002008
Dutchwest Natural Vent Gas Heater LIMITED LIFETIME WARRANTY PRODUCT COVERED BY THIS WARRANTY All Dutchwest gas stoves equipped with an Insta-Flame Ceramic Burner. BASIC WARRANTY CFM Corporation Company (hereinafter referred to collectively as the Company) warrants that your new Dutchwest Gas Fireplace/Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions and limitations.
Efficiency Ratings Model 2467 2468 EnerGuide Ratings Fireplace Efficiency (%) 51.4 51.4 CFM Corporation 2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www.cfmcorp.