If the fan is not functioning after installation:
Step 1. Check to make sure that batteries are installed
correctly in the control.
Step 2. Turn the power off to the fan (from the circuit
breaker) for at least 5 seconds.
Step 3. Turn the power back on (at the circuit breaker) and
push the HIGH, MED, and LOW buttons–in that order–
within 20 seconds.
Step 4. The fan should now function properly.
CHANGING TRANSMITTER FREQUENCY SETTING
You will only have to change the dip switch settings in the
remote if you are using more than one fan in the same area
and want to control them separately.
Step 1. At the circuit breaker or fuse box, turn the power
off for the fan you want to change.

and remove the batteries.
Step 3. Change the dip switch settings, assuring that they
      
fan.
Step 4. Re-install the batteries and the battery door on the con-
trol.
Step 5. At the circuit breaker or fuse box, turn the power
back on for the fan whose frequency you are changing.
Step 6. Within 20 seconds of restoring power, push the
HIGH, MED, and LOW buttons (in that order).
Circuit Breaker
or Fuse Box
Press in this order to set new
frequency:
1. HIGH 2. MED 3. LOW
Dip Switch
Set to “01001”
Dip Switch
Set to “10000”
Versa•Touch 2
Control
(back)
1
2
3
Note: You may want to label your controls to assure
you do not mix them up.
WARNING!
Do not turn the power off at the circuit
breaker, then back on, for the previously
installed Versa•Touch2 fan(s), as you may
inadvertently change the frequency settings
for it as well.
