ODSHR Series Outdoor Woodburning Fireplace Homeowner's Installation and Operating Manual Model: ODSHR42 1384 SHR cover 5/27/99 djt Underwriter's Laboratories Report No. MH20546 DO NOT DISCARD THIS MANUAL: Retain for future use. 20002264 10/06 Rev.
ODSHR Outdoor Woodburning Fireplace Table of Contents PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING FIREPLACE. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Specifications and Framing Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . .
ODSHR Outdoor Woodburning Fireplace Safety Information NOTE: This unit is intended for outdoor use in the United States using CF11 or SK chimney systems. The unit may be installed indoors, in the U.S. only, using CF11 chimney system only. This unit is intended for outdoor use in Canada using the SK chimney system only. Do not obstruct or modify air inlets/outlets in any Description manner. The ODSHR Series (Super Hearth) fireplace is a cleanfaced, solid fuel, woodburning fireplace.
ODSHR Outdoor Woodburning Fireplace ODSHR42 Series Woodburning Fireplace Minimum Rough Opening Depth 62���" (1578 mm) ��" (889 mm) 13���" Dia. (340 mm) �����" 264 mm) �����" (280 mm) �� ��� �" (1 ��� 13 "( 2m �� 19 m ��� mm ) "( ) 22 32 m m ) ���" 62���" (1578 mm) ���" Minimum Rough Opening Height ���" 15���" (397 mm) Outside Air 11" Dia.
ODSHR Outdoor Woodburning Fireplace Chase Installation Exterior Chase Installation Insulation methods shown are optional for cold climate, not a requirement for unit operation or exterior installation .
ODSHR Outdoor Woodburning Fireplace Chimney Requirements - Offset Installations OFFSET CHIMNEY FLUE EXIT RISE CHIMNEY SECTION IWF282 D E 6 FT. C G 30˚ OFFSET ELBOW RISE H OFFSET 30˚ RETURN ELBOW 30˚ OFFSET ELBOW B G 11CS SUPPORT H HEARTH FLOOR Example 1 Example 2 Notes: G + H cannot exceed 20 feet (610cm). *11CF Chimney airspace clearance = 2" (51mm) minimum.
ODSHR Outdoor Woodburning Fireplace Planning Information Preplanning an installation is very important to ensure safety and to save time and money. An installer must predetermine where a fireplace will be set and how the chimney system will be run. Mounting the Fireplace A fireplace may only be mounted on the following surfaces: 1. A flat combustible surface. 2. A raised wooden platform. 3. A concrete block or other solid object placed beneath each of the four (4) corners of the fireplace.
ODSHR Outdoor Woodburning Fireplace Installation Chimney Supports The chimney system is supported by the fireplace for vertical chimney heights less than 30' (9 m) above the hearth. Chimney supports are required if the vertical height exceeds 30' (9 m) with 11CF chimneys. Locate chimney supports at ceiling holes or other structural framing at 30 foot heights. Spacing between chimney supports must not exceed 30' (9 m). Use Chimney Support Model 11CS.
ODSHR Outdoor Woodburning Fireplace Framing Framing can be constructed before or after the fireplace is set in place, however, most installers build the frame before setting the fireplace. Frame fireplace with 2 x 4 lumber or heavier materials. Refer to framing dimensions in Figures 1, 2 or 3 for basic fireplace specifications. NOTE: Framing should be positioned to accommodate wall covering and fireplace facing material.
ODSHR Outdoor Woodburning Fireplace Cutting the Hole Cover fireplace collar opening and cut proper sized chimney hole in chimney. Existing Ceiling Joists 17¹⁄₂" (445 mm) 17¹⁄₂" (445 mm) Chimney Hole Framing the Ceiling Hole Frame the ceiling chimney hole as shown in Figure 13. It is good practice to use framing lumber that is the same size as the ceiling joists; this is a requirement at attic level.
ODSHR Outdoor Woodburning Fireplace Positioning, Safety Strips, Securing the Fireplace Slide fireplace into position. Metal Safety Strips (1, 2 or 3 pieces) Lift the fireplace front slightly and slide the metal safety strips under front bottom edge about 1¹⁄₂" (38 mm), allowing the remainder to extend in front of firebox. Overlap strips at least 1/2" (13 mm) to provide a positive joint. (Flat safety strips are packed with fireplace.) (Fig.
ODSHR Outdoor Woodburning Fireplace Installing the Chimney System Inner Pipe Section Start by attaching the first chimney section to the collar on top of the fireplace. UP Install the pipe as pictured in Figure 17. When you get a good lock, you will hear the pipe clearly snap together. Once sections are snap-locked in place, it is extremely difficult to get them apart. Make sure the pipe is firmly snapped and locked together as each pipe section is mounted.
ODSHR Outdoor Woodburning Fireplace Firestop spacers are not available for, nor are they required on, vertical walls. WARNING: DO NOT PACK REQUIRED AIR SPACES WITH INSULATION OR OTHER MATERIALS. The CFM Corporation chimney components have been tested and approved with the area where the outer pipe slides through the firestop spacer sealed with a noncombustible caulk if desired, or left completely open with no sealant. Mark an outline of the roof hole around the centerpoint of the nail.
ODSHR Outdoor Woodburning Fireplace Air Space Clearances Combustible framing material MUST NOT penetrate AIR SPACE (shaded areas) Finished Wall Stud Noncombustible Decorative Facing 2 x 4 Header 2" Must be Sealed Ledge Bracket with Noncombustible Material Standoff ³⁄₄" Air Space to Sides Front View Side View Side View Surround FP1166 Firestop Wall Shield Fig. 21 Fireplace surround flush with finished wall.
ODSHR Outdoor Woodburning Fireplace Mantel Clearance No Noncombustible Facing Material 12" (305mm) Max. Combustible Mantel and Trim 1¹⁄₂" Combustible Mantel and Trim Finished Wall Header Noncombustible Material Header Surround Face Standoff 12" (305mm) min. Noncombustible Material Surround Face 6" (159mm) Min. Noncombustible Facing Material Fireplace Opening * Minimum width from top of surround to bottom of screen rail Finished Wall 1¹⁄₂" Standoff 12" (305mm) min. * 12" (305mm) Max.
ODSHR Outdoor Woodburning Fireplace 40" Min. Side Wall Protection Adjacent combustible side walls that are within dimensions shown in Figure 25 of fireplace opening must be protected with CFM Corporation Wall Shield Model SP40 or a specifically built wall shield described in Figure 26. 40" Min. The special wall shield design described in Figure 26 is an alternate method of adding protection to side walls and can be used in place of the SP40 with the same wall clearances specified for the SP40. Rt must =1.
ODSHR Outdoor Woodburning Fireplace Alternate noncombustible materials may be used providing the (total) thermal resistance (Rt value) of the alternate material employed is greater than or equal to R = 1.09. Thermal resistance (R) or thermal conductivity (K), may be obtained from manufacturer of the material. Factors are related by the formula K = 1/R. (Fig.
ODSHR Outdoor Woodburning Fireplace Wall Covering 2 x 4 Header - Do Not Notch at Ledge Brackets Noncombustible Decorative Facing Seal All Cracks Between Fireplace Surround and Wall Materials with Noncombustible Material Noncombustible Decorative Covering Hearth Extension Majestic Safety Strips Must be Overlapped 1/2" Min. Fig. 19 BTU input of a gas appliance installed in fireplace should be rated less than 100,000 BTU/Hr.
ODSHR Outdoor Woodburning Fireplace 1 2 3 9a,b 4 8 6 10 7 5 11 13 12 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. ODSHR Outdoor Woodburning Fireplace Ref. 1. 2. 3. 4. 5. 6. 7. 8. 9a. 9b. 10. 11. 12.
ODSHR Outdoor Woodburning Fireplace Accessories The following accessories for this appliance are available from your local CFM Corporation products distributor. Should you need additional information beyond what your distributor can furnish, contact: CFM Corporation, 2695 Meadowvale Blvd., Mississauga, Ontario, Canada L5N 8A3, Attn: Technical Services. CAUTION: This fireplace and chimney assembly is a highly engineered system, and, as such, must be operated only with CFM Corporation approved components.
ODSHR Outdoor Woodburning Fireplace Accessory Description Extended Round Top For use with Type "11CF" Chimney Systems. Used to terminate chimney at top of chase. Adapter kit included. Flashing not included. Chimney Sections Used to build "11CF" chimney systems. Chimney Elbows Used to develop 30° offset chimney systems. (Elbows packed 2 per carton - upper and lower elbow set) Top Housing with Upper Baffle Gives traditional chimney top look using simulated brick in red, tan or white color.
ODSHR Outdoor Woodburning Fireplace 22 20002264
ODSHR Outdoor Woodburning Fireplace LIMITED WARRANTY & 30 YEAR PROTECTION PLAN For Majestic Fireplaces PRE-ENGINEERED Fireplace Systems CFM Corporation warrants its Pre-Engineered Fireplace (“Fireplace”) and the CFM Corporation-supplied firegrate, glass doors, outside air system, fan motor, and liners to be free from defects in material or workmanship, as follows: A.
CFM Corporation 2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www.cfmcorp.