INSTALLER / CONSUMER SAFETY INFORMATION Please read this manual before installing and using appliance. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. —Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. —WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance.
Radiance Vent-Free Gas Heater Table Of Contents PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Vermont Castings stove. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Installation and Operating Instructions ..................................................................................
Radiance Vent-Free Gas Heater Installation & Operating Instructions In order to ensure safe and effective installation, this unit must be installed only by a qualified agency, individual, firm, corporation or company that is experienced in the installation, repair and servicing of this type of appliance and is familiar with the building codes and installation techniques appropriate in your area. Contact your hearth products dealer or local gas supplier for the name of a qualified service person.
Radiance Vent-Free Gas Heater Radiance Vent Free Gas Heater Dimensions 29���" (756mm) RADIANCE 28���" (717mm) 6���" (165mm) 31" (787mm) 4 11" (279mm) 18���" (465mm) Drawing Not to Scale Fig. 1 Radiance Vent Free dimensions.
Radiance Vent-Free Gas Heater Clearance Requirements A Minimum Clearances to Combustible Materials B Maintain clearance, (empty space), between combustible materials and the heater as specified below. C V D W A B Wall E X Y Z ST694 ST101 A: To Side Wall / Trim*......................... 4” (101.6mm) ST101 B: To Rear Wall ................................... 4” (101.6mm) Min.
Radiance Vent-Free Gas Heater High Elevations Gas Specifications Model RUVSODRN RUVSODRP Fuel Nat. Prop Gas Control Millivolt Millivolt Firebox weight / shipping Max. Input BTU/h 35,000 35,000 Min. Input BTU/h 26,000 26,000 175 lbs. Gas Inlet and Manifold Pressures Inlet Minimum Natural 5.5” w.c. LP (Propane) 11” w.c. Inlet Maximum 14” w.c. 14” w.c. Manifold Pressure 3.5” w.c. 10” w.c. (MP) 11” w.c. (RP) Radiance RUVSODRN/RP Vent-Free Certified to: ANSI Z21.11.
Radiance Vent-Free Gas Heater Vent Free Features The Radiance RUVSOD, Model Nos. 3357, 3358, 3370 thru 3379, is an unvented gas heating appliance tested and listed to the ANSI standard Z21.11.2-2000. This appliance is specifically configured to burn either Natural Gas or Propane fuel, as indicated on the metal rating plate attached to the rear shroud. The Radiance RUVSOD is not fuel convertible. The RUVSOD is shipped fully assembled with the exception of the log set.
Radiance Vent-Free Gas Heater 2. Divide the volume of space by 50 cubic feet. The result is the maximum BTU/Hr that the space can support. Example: 3840 divided by 50 = 76.8 or 76,800 BTU/Hr. 3.
Radiance Vent-Free Gas Heater Assembly Procedures Read these instructions thoroughly before starting the assembly. Follow procedures in the order given. Inspect the stove for damage before starting the assembly. Do not install this stove if any damage is evident. Contact your dealer immediately. The Radiance is shipped on its back, mounted to a wooden pallet. It is fully assembled, although packing materials must be removed from the firebox and the Log Set installed.
Radiance Vent-Free Gas Heater Assemble the Legs 1. Slide stove to the rear of the pallet just far enough to access rear leg holes. Make sure the stove does not tip over backwards. (Fig. 7) 6. Remove pallet and allow stove to gently rest on all four legs. 7. Adjust leg levelers to compensate for irregularities in the hearth. Install Optional Fan It is easiest to install the optional fan kit #2767/FK26, before the stove is moved to its final location or connected to the gas line.
Radiance Vent-Free Gas Heater 4. Attach the fan assembly to the fan bracket provided in the log box. Use #10 sheet metal screws provided with fan kit. Do not remove finger guard screws.(Fig. 10) Snapstat Wire Rheostat Wire Fan Bracket 6. Position the fan assembly so the ducts slide between the inner and outer shroud. The inner shroud should engage with the two slots in the ends of the bracket so that bracket and shroud are interlocked. (Fig.
Radiance Vent-Free Gas Heater Install ON/OFF Switch The switch assembly parts are found in the parts bag. 1. Attach switch assembly to left rear side of stove shroud using two screws and existing holes in shroud. (Fig. 16) 2. Run wires down back of stove, under bottom of rear shroud to valve. 3. Attach wires to valve terminals. (Fig. 17) Rheostat Retaining Nut Control Knob ST347a Switch Assembly Existing Holes Fig. 14 Attach rheostat to control panel. Valve may look different.
Radiance Vent-Free Gas Heater On/Off Switch Wiring Thermopile Black 4. Replace burner. Slide the burner in at an angle with left side lower than the right side. Slide the left side onto the injectors, making sure the burner leg remains at a 90° angle to the base. (Fig. 19) Lower the right hand side down in to place. Make sure the burner is as far left as possible and the injector shoulders are inside the burner.
Radiance Vent-Free Gas Heater 8. Install glass frame assembly by resting the bottom edge of the frame on support brackets below the front opening of the firebox. Swing the top edge of the assembly toward the firebox, and center it. Fasten by closing the latches over the top left and right edges of the frame. (Fig. 22) CAUTION This appliance should only be connected by a qualified gas technician. Test to confirm manifold pressures as specified below.
Radiance Vent-Free Gas Heater Complete the Installation Right Log Right Rear Log Left Rear Log Left Bracket LG171 Decorative Grate Right Bracket Fig. 23 Install the left and right rear logs and the right log. LG156 Radiance logs 4/23/01 djt Log rests on decorative grate 1. Replace the screen frame by sliding the hooks over the top front edge of the firebox and resting the bottom on the support brackets.
Radiance Vent-Free Gas Heater Operation The Radiance is shipped with the operable door front plate. The stove may be operated with the doors either open or closed. To open the front doors, insert the handle provided into the door latch stub and turn it to the right and up. (Fig. 28) When not in use, the handle may be stored in the handle holder on the right side of the rear shroud. (Fig. 29) Natural Pilot Counterclockwise to Open ST673 LP Pilot ST673location. Fig.
Radiance Vent-Free Gas Heater Lighting And Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manually. When lighting the pilot follow these instructions exactly. B. BEFORE LIGHTING smell all around the heater area for gas.
Radiance Vent-Free Gas Heater Troubleshooting Follow these procedures in the order presented. WARNING TURN OFF HEATER AND ALLOW TO COOL COMPLETELY BEFORE SERVICING. CONDITION POSSIBLE CAUSE SOLUTION No spark at pilot when Ignitor is operated. 1. Ignition Electrode is disconnected from ignition wire, broken or incorrectly positioned. 2. Ignitor wire is broken. 3. Bad Piezo Ignitor. 1. Inspect and re-connect, replace or repair as necessary. 1.
Radiance Vent-Free Gas Heater Troubleshooting cont’d. CONDITION POSSIBLE CAUSE SOLUTION Pilot lights but flame goes out when Control Knob is released. 1. Control Knob not fully depressed or held in long enough. 2. Gas supply line shut-off valve is not fully open. 3. Thermocouple connection is loose at the Control Valve. 1. Depress Control Knob fully and hold in for a full 30 seconds. 4. Pilot flame does not touch the Thermocouple.
Radiance Vent-Free Gas Heater Maintenance The following procedures will help ensure that your heater continues to perform safely and efficiently. Screen Hooks Firebox Cleaning and Inspection Cleanliness is critical to correct operation of the heater. The log set, burner, valve controls and air circulation areas must all be kept free of dust and unobstructed by debris. Inspect these areas before each use and clean whenever accumulation is evident. Follow the simple procedure outlined below.
Radiance Vent-Free Gas Heater Catalytic Combustor The combustor should be cleaned annually to ensure optimal performance. Follow the procedure below. Remove the Combustor Module 1. Be sure the heater is COLD. 2. Remove the front plate, top grille and screen. (Fig. 36) 3. Use the phillips screwdriver to remove the two sheet metal screws that secure the combustor to the top of the firebox. (Fig. 37) Use a flat screwdrive to lift the unit up and out through the front of the stove. Clean the Combustor Module 1.
Radiance Vent-Free Gas Heater 5 6 2 1a 3 4 25 7 1b 1c 8 9 17 PILOT ADJ 11a 16 I L ON 11b O H 18 PI LO T OFF 10a,b 12a,b 15 14 19 13 20 23 21 27 28 22 30 24a,b, c,d 29 4555 CFM Specialty Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. Radiance Vent Free Gas Heater (RUVSOD) Models 3357, 3358, 3370 thru 3379 4555 Ref. 1. 1a. 1b. 1c. 2. 3. 4. 5. 6. 7.
Radiance Vent-Free Gas Heater Radiance Vent Free Gas Heater (RUVSOD) Models 3357, 3358, 3370 thru 3379 (continued) Ref. 8. 9. 10a. 10b. 11a. 11b. 12a. 12b. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24a. 24b. 24c. 24d. 25. 26. 27. 28. 29. 30. 31. Description Handle Package, Ceramic w/Screw Damper Steel Handle/Screw Valve NG Honeywell - VS84212003 Valve LP Honeywell - VS84212011 Oxygenerator, NG OP #8204 Oxygenerator, LP OP #8404 Burner Housing Assy. - RUVSODRN Burner Housing Assy.
Radiance Vent-Free Gas Heater Optional Accessories Fan Kits FK26 Fan The FK26 fan helps distribute heated air from within the firebox out into the room. The fan is controlled by a snapstat that turns power on and off as the firebox temperature rises above and falls below a preset temperature. A rheostat provides for variable fan speeds. Specifications Maintenance The fan itself does not require regular maintenance, however, periodic cleaning of the fan and the surrounding area is required.
Radiance Vent-Free Gas Heater 20004555 25
Radiance Vent-Free Gas Heater 26 20004555
LIMITED LIFETIME WARRANTY Radiance Vent-Free Gas Heater PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic or Northern Flame brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner.
CFM Specialty Home Products 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www.majesticproducts.com • www.vermontcastings.