SR/SC Series "A" Woodburning Fireplace For Models: SC36A, SR36A SC42A, SR42A Homeowner's Installation and Operating Manual 948 SR cover 11/18/97 948 SC cover 11/18/97 For use in U.S./Canada Underwriter's Laboratories Report No. MH7603 DO NOT DISCARD THIS MANUAL: Retain for future use. 7412948 1/13 Rev.
SR/SC Series "A" Woodburning Fireplace Safety Information Please read this manual before installing and using FIREPLACE. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Description The SR/SC Series "A" fireplaces are solid fuel, woodburning premium fireplaces.
SR/SC Series "A" Woodburning Fireplace SR36A Series Woodburning Fireplace 4856O" (1232mm) 5/8”(13mm) 2256O" (572mm) 11" Dia. (279mm) 856M" (210mm) 8" Dia.
SR/SC Series "A" Woodburning Fireplace SR42A Series Woodburning Fireplace 2656M" (667mm) Rough Opening Depth 50" (1270mm) 1/2" (13mm) 11" Dia. (279mm) 8" Dia.
SR/SC Series "A" Woodburning Fireplace B C A FP1531 Front Width Back Width SR/SC36A SR/SC42A Depth A B C FP1531 31¹⁄₈" 19⁷⁄₈" 15¹⁄₂" hearth dimensions (791 mm) (505 mm) (394 mm) 9/04 djt 36³⁄₄" 22⁷⁄₈" 15¹⁄₂" (934 mm) (581 mm) 394 mm) Fig. 4a Hearth dimensions. Chase Installation Insulation methods shown are optional for cold climate, not a requirement for unit operation.
SR/SC Series "A" Woodburning Fireplace Chimney Requirements - Offset Installations OFFSET CHIMNEY FLUE EXIT RISE CHIMNEY SECTION IWF282 30° RETURN ELBOW B A D E 6 FT. G 30° OFFSET ELBOW RISE C H OFFSET 30° RETURN ELBOW 30° OFFSET ELBOW B 30° Elbow Offsets G SKCS8 SUPPORT H HEARTH FLOOR Example 1 Example 2 Example 3 IWF269 Notes: G + H cannot exceed 20 feet.
SR/SC Series "A" Woodburning Fireplace Planning Information Preplanning an installation is very important to ensure safety and to save time and money. An installer must predetermine where a fireplace will be set and how the chimney system will be run. Mounting the Fireplace A fireplace may only be mounted on the following surfaces: 1. A flat combustible surface. 2. A raised wooden platform. 3. A concrete block or other solid object placed beneath each of the four (4) corners of the fireplace.
SR/SC Series "A" Woodburning Fireplace Chimney Supports The chimney system is supported by the fireplace for vertical chimney heights less than 30' (9 m) above the hearth. Chimney supports are required if the vertical height exceeds 30' (9 m) with SK8 chimneys or 20' (6 m) with 3wall chimneys. Locate chimney supports at ceiling holes or other structural framing at 30' (9 m) (SK8) or 20' (6 m) (3-wall) heights. Spacing between chimney supports must not exceed 30' (9 m) (SK8) or 20' (6 m) (3-wall).
SR/SC Series "A" Woodburning Fireplace Framing Option For Circulating Models Only — Framing can be constructed before or after the fireplace is set in place, however, most installers build the frame before setting the fireplace. Frame fireplace with 2 x 4 lumber or heavier materials. Refer to framing dimensions in Figures 1, 2, 3 or 4 for basic fireplace specifications. Note: Framing should be positioned to accommodate wall covering and fireplace facing material.
SR/SC Series "A" Woodburning Fireplace Straight-Up Chimney Installation To mark the centerline of the flue, put the fireplace in final position and measure out from the wall: 9¹⁄₄" (235 mm). Mark a spot on the ceiling directly above the fireplace. Draw a line parallel to the back wall through this mark. (Fig. 11) Using a plumb bob positioned directly over center point of fireplace flue collar, mark the ceiling to establish the chimney center point. (Fig.
SR/SC Series "A" Woodburning Fireplace The following table gives firestop spacer model numbers: Angle of Chimney at Ceiling Size of Chimney Vertical 30° 8" Flue SKFS2A SKFS6A "SK" Series 14¹⁄₂" x 14¹⁄₂" 14¹⁄₂" x 25¹⁄₂" (368mm x 368mm) (368mm x 648mm) 8" Flue FS2A FS6A "S" Series 3-Wall 17¹⁄₂" x 17¹⁄₂" 17⁷⁄₈" x 29⁵⁄₈" (445mm x 445mm) (454mm x 753mm) Fig. 13 Ceiling chimney hole sizes necessary for installing firestop spacer.
SR/SC Series "A" Woodburning Fireplace Continue installing the pipe as required until pipe is installed up through the ceiling. At this point, you must install a firestop spacer. Pipe Section Installing the Firestop Spacer in the Ceiling Hole Pipe Rim UP Hem A firestop spacer is used to keep pipe spaced properly and required for safety. Lance Pipe Rim Nail the firestop spacer (at each corner) to the framing members of the ceiling hole. NOTE: A firestop spacer is not required at the roof.
SR/SC Series "A" Woodburning Fireplace Install the attic insulation shield with the flanges on its base extending down into the framing hole. Nail each corner of attic insulation shield to the framing members of the ceiling hole using 8d nails. Attic shields are not required at the roof. Penetrating the Roof Run pipe to roofline. Since the chimney system must be vented to the out-of-doors, you must use an approved termination.
SR/SC Series "A" Woodburning Fireplace Installing Top Housing or Termination Air Space Clearances Combustible framing material MUST NOT penetrate AIR SPACE (shaded areas). Follow the installation instructions provided with the chimney termination you have selected. Installing Chimney In a Chase Refer to Page 5, Figure 5 for an illustration of a typical chase installation. CAUTION: Treatment of firestop spacers and construction of chase may vary with type of building.
SR/SC Series "A" Woodburning Fireplace Mantel Clearance - Radiant Model - No Noncombustible Facing Material Combustible Mantel and Trim 12" (305mm) Max. 156O" (38mm) Mantel Clearance - Radiant Model - with Noncombustible Facing Material Combustible Mantel and Trim Finished Wall 156O" (38mm) Header 12" (305mm) Min. 12" (305mm) Max. 12" Standoff Noncombustible (305mm) Min. Material Radiant Surround Face * 6" (159mm) Min.
SR/SC Series "A" Woodburning Fireplace Side Wall Protection Hearth Installation Adjacent combustible side walls that are within the minimum dimensions shown in Figure 23 of fireplace opening must be protected with a specifically built wall shield as described below. A hearth extension is required to protect a combustible floor in front of the fireplace. Refer to Figure 23 for minimum dimensions and mounting detail. NOTE: Hearth Extension must not cover the air inlet opening of a fireplace.
SR/SC Series "A" Woodburning Fireplace COMMON MATERIALS AND FACTORS MATERIAL EH2416 Micor 300 R K* 0.458 1.09 Common Brick 5.0 0.10 MINIMUM THICKNESS Side View Wall Covering Noncombustible Decorative Facing 0.50 in.** 2 x 4 Header (Do not notch at standoffs) Seal all cracks between fireplace surround and wall materials with noncombustible material 5.46 in.** R Value is for 1/2 inch.
SR/SC Series "A" Woodburning Fireplace Installing Line for Gas Logs Vermont Castings Group fireplaces are designed to accept a 1/2" (13 mm) gas line for installation of an approved gas appliance. (Vermont Castings Group manufactures a wide variety of gas logs for use in Vermont Castings Group fireplaces.) Fireplace Top View Hole in Outer Casing Gas Line Tube Be sure to have the appliance installed in accordance with building codes. 1" Min.
SR/SC Series "A" Woodburning Fireplace 1 8 2 9 4 5 b c d 3 a e 7 10 6 11 12 Vermont Castings Group reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. SR36A/42A, SC36A/42A SERIES Ref. 1. 2. 3. 4. 5a. 5b. 5c. 5d. 5e. 6. 7. 8. 9. 10. 11. 12.
SR/SC Series "A" Woodburning Fireplace Accessories The following accessories for this appliance are available from your local Vermont Castings Group Fireplaces distributor. Should you need additional information beyond what your distributor can furnish, contact: Vermont Castings Group, 149 Cleveland Drive, Paris, KY 40361, Attn: Technical Services. CAUTION: This fireplace and chimney assembly is a highly engineered system, and, as such, must be operated only with Vermont Castings Group approved components.
SR/SC Series "A" Woodburning Fireplace Chimney Components U.S. Component Round Top Termination Description Top used to terminate chimney at roof. (Flashing not included.) Round Top Termination Top used to terminate chimney at chase. Extended (Flashing not included.) Flashing Metal finishing required around Contemporary Termination to prevent rain leakage. Square Termination Top housing of simulated brick pattern Housing available in red, tan or white. Appropriate adapter required.
SR/SC Series "A" Woodburning Fireplace (Chimney Components con't.) Canada Component Chimney Collar Enclosure Attic Insulation Shield SK8 Chimney Sections 45˚ Chimney Elbows 22 Description Installs on the "over the chimney collar" of the fireplace; provides outside air to assist in cooling the chimney system. Used to prevent insulation from coming in contact with the chimney system. Used to build chimney systems exposed above roof. Provides 45˚ offset and return.
SR/SC Series "A" Woodburning Fireplace LIMITED WARRANTY Factory-Build Fireplace and Components (Except Blowers) What is Covered and For How Long Five-Year Coverage: For five years from the date this fireplace and components are first purchased for use, Vermont Castings Group will, at its option, repair or replace any defective part of this fireplace or components, or refund to you a sum not to exceed the factory retail price in effect at the time of purchase.
Vermont Castings Group 149 Cleveland Drive • Paris, Kentucky 40361 www.vermontcastingsgroup.