Specifications
22
Intrepid
®
II Woodburning Stove
2000966
To open the front doors, insert the handle into the door
latch stub and turn it to the left and up. To close them,
always close the left door rst. Turn the handle in the
right door to the left and up (to the open position) and
close the door. Push on the door as you turn the handle
to the right and down. The doors will draw in slightly,
and the handle should offer some resistance as you
turn it to the closed position. (Fig. 37)
Avoid striking the glass or slamming the doors to re-
duce the risk of breaking the glass.
When you’re not using the door handle, store it in the
holder behind the right front leg of the stove.
ST522
Intrepid
close doors
11/00
Open
Position
Closed
Position
ST522
To open the front doors, turn handle clockwise.
The Intrepid II is designed to burn natural wood only; do
not burn fuels other than that for which it was designed.
You’ll enjoy the best results when burning wood that
has been adequately air-dried. Avoid burning “green”
wood that has not been properly seasoned. The wood
should be 16” (410mm) in length.
The best hardwood fuels include oak, maple, beech,
ash, and hickory that has been split, stacked, and air-
dried outside under cover for at least one year.
For areas that do not have a supply of hardwood, com-
monly burned softwoods include tamarack, yellow pine,
white pine, Eastern red cedar, r, and redwood. These
too should be properly dried.
Store rewood under cover to keep it dry. Dry, well-sea-
soned wood is best for heating and re-viewing. How-
ever, avoid wood dried more than two years. This wood
burns very quickly, reducing burn time.
Even for short-term storage, keep wood a safe distance
from the heater and keep it out of the areas around the
heater used for refueling and ash removal.
An optional surface thermometer tells you when to
adjust the air control, when to refuel, and helps to tell
when your catalyst is operating properly.
For example, when the thermometer registers at least
450°F (230°C) after start-up you know the stove is hot
enough to begin catalytic combustion and it may be
time to close the damper.
Place the thermometer in the center of the griddle, as in
Figure 38, and use the following temperature ranges as
a guide to operation:
When thermometer readings drop below 350°F (175°C)
it’s time to adjust the air control for a higher burn rate or
to reload the stove.
• A temperature reading over 750°F (400°C) is a sign
to cut back on the air supply to slow the burn rate.
• Readings in the 300-400°F (150-200°C) range indi-
cate low to medium heat output.
• Readings of 500-650°F (260-340°C) indicate high
heat output. Operating your Intrepid II continuously
at griddle temperatures of 750°F (400°C) or higher
may damage inner parts or the enamel nish.
ST523
Intrepid
temp readings
11/00
ST523
Take temperature readings with a thermometer lo-
cated in the middle of the griddle.