Installation Instructions

1515
3-Wire Conduit Installation
(See Figures 3.1, 3.5 and 3.6)
1. Remove the
Terminal Block Access Plate
on the back of the
range by unscrewing the 6 fixing
Screws
(fig. 3.1).
2. Feed 3/4” trade size
Conduit
through the hole in the
Conduit
Bracket
and secure to the
Conduit Bracket
with a
Conduit
Clamp
.
3. Remove the 3 wire terminal nuts and washers from the
Terminal Block
.
4. Plug the terminal holes of conductors. The
Neutral or Ground
Wire
of the
Power Cord
must be connected to the neutral
terminal located in the center of
Terminal Block
. The
Power
Wires
must be connected to the outside terminals.
5. Plug washers and tighten nuts securely.
Do not remove
Ground strap
.
6. Assemble the
Terminal Block Access Plate
.
4-Wire Conduit Installation
(See figures 3.1, 3.5 and 3.7)
1. Remove the
Terminal Block Access Plate
on the back of the
range by unscrewing the 6 fixing
Screws
(fig. 3.1).
2. Feed 3/4” trade size
Conduit
through the hole in the
Conduit
Bracket
and secure to the
Conduit Bracket
with a
Conduit
Clamp
.
3. Remove the 3 wire terminal nuts and washers from the
Terminal Block
.
4. Remove the
Ground Strap
from the frame of range and
terminal by removing its screw and cutting it as shown in
figure 3.7.
5. Plug the terminal holes of conductors. The
Neutral Wire
of
the
Power Cord
must be connected to the neutral terminal
located in the center of
Terminal Block
; the
Power Wires
must
be connected to the outside terminals; the
Ground Wire
must
be attached to the frame of range by using the
(Ground)
identified
Grounding Screw
.
6. Plug washers and tighten nuts securely.
7. Assemble the
Terminal Block Access Plate
.
Hole D 1" 1/8
(28.58 mm)
Counduit
Bracket
Power Wires
Terminal Block
Ground strap
Neutral Wire
Conduit
Conduit Clamp
Fig. 3.5
Fig. 3.6
Fig. 3.7
2