Installation Instructions

21
1
2
NATURAL GAS
REGULATION
LP/PROPANE
REGULATION
A
component
Fig. 2.5
REGULATOR
COVER
Pressure
regulator
CONVERSION TO LP/PROPANE GAS (OR CONVERSION
BACK TO THE ORIGINAL GAS - NATURAL GAS)
Every range is provided with a set of injectors for the various types of gas.
Select the injectors to be replaced according to the “INJECTORS TABLE”.
The nozzle diameters, expressed in hundredths of a millimetre, are marked on the
body of each injector.
CAUTION: Save the orifices removed from the appliance for future use.
SETTING THE PRESSURE REGULATOR (fig. 2.5)
The pressure regulator is accessible through the storage compartment by opening
the bottom pivoting panel; the pressure regulator is positioned on the rear right side
of the range.
To set the pressure regulator:
1. Unscrew the regulator cover;
2. Unscrew the A component, reverse and screw it according to the LP/PROPANE (or
NATURAL GAS) regulation.
2