SETTING THE BURNER MINIMUM
When switching from one type of gas to another, the minimum ow rate must also be correct: the ame should not go out even when
passing suddenly from maximum to minimum ame.
To regulate the ame (g. 2.7) follow the instructions below:
Triple-ring and semirapid burner
Light the burner.
Set the gas valve to position (minimum rate).
Remove the knob.
With a thin screwdriver, turn the regulation screw “R
1
” until adjustment is correct.
Inside crown of DUAL burner
Light the DUAL burner.
Set the gas valve to position (minimum rate of inner crown).
Remove the knob
With a thin screwdriver, turn the regulation screw “R
2
” until adjustment is correct.
Outside crown of DUAL burner
Light the DUAL burner.
Set the gas valve to position (minimum rate of outer crown and maximum rate of inner crown).
Remove the knob.
With a thin screwdriver, turn the regulation screw “R
3
” until adjustment is correct.
For LP/PROPANE gas, tighten the adjustment screws completely.