Owner's manual

e1mdlCsmFP-rev0314
www.versamati c .com
3 • Model E1 Metallic Bolted
Performance
E1 1" Bolted Metal
Rubber and TPE Fitted
Flow Rate
Adjustableto .......0-46gpm(174.1lpm)
Port Size
Suction ............... 1½"TRI-CLAMP
Discharge............. 1½"TRI-CLAMP
Air Inlet ......................3/8"NPT
Air Exhaust ..................1/2"NPT
Suction Lift
Dry ........................16'(4.9m)
Wet........................31'(9.4m)
Max Solid Size(Diameter)
........................1/8"(3.2mm)
Max Noise Level .............93dB(A)
Shipping Weights
Stainless Steel ...........36lbs(16.3kg)
E1 1" Bolted Metal
PTFE Fitted
Flow Rate
Adjustableto .......0-36gpm(136.3lpm)
Port Size
Suction ............... 1½"TRI-CLAMP
Discharge............. 1½"TRI-CLAMP
Air Inlet ......................3/8"NPT
Air Exhaust ..................1/2"NPT
Suction Lift
Dry ........................11'(3.4m)
Wet........................31'(9.4m)
Max Solid Size(Diameter)
........................1/8"(3.2mm)
Max Noise Level .............96dB(A)
Shipping Weights
Stainless Steel .............36lbs(16.3kg)
NOTE: Performance based on the following: PTFE tted pump, ooded suction, water at ambient conditions.
The use of other materials and varying hydraulic conditions may result in deviations in excess of 5%.
NOTE: Performance based on the following: elastomeric tted pump, ooded suction, water at ambient conditions.
The use of other materials and varying hydraulic conditions may result in deviations in excess of 5%.
0 20 40 60 80 100 120 140
Discharge Head in PSI
Meters Feet
240
220
200
180
160
140
120
100
80
60
40
20
0
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
0
1
3
2
4
5
6
7
BAR
Capacity in Liters Per Minute
Capacity in U.S. Gallons Per Minute
Capacity Per Stroke: 0.047 Gal (0.18 L)
0
20
40
60
80
100
5
10
15
20
25
30
35
40
5
10
20
30
AIR CONSUMPTION IN SCFM
AIR PRESSURE IN PSI
SCFM M
3
/HR
5 8.5
10 17
20 34
30 51
0 20 40 60 80 100 120 140 160 180
Discharge Head in PSI
Capacity in Liters Per Minute
Capacity in U.S. Gallons Per Minute
0
20
40
60
80
100
0 5 10 15 20 25 30 35 40 45 50
5
10
20
30
Meters Feet
240
220
200
180
160
140
120
100
80
60
40
20
0
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
0
1
3
2
4
5
6
7
BAR
AIR CONSUMPTION IN SCFM
AIR PRESSURE IN PSI
SCFM M
3
/HR
5 8.5
10 17
20 34
30 51
Displacement Per Stroke,
.09 Gal. (0.34 L)
1: PUMP SPECS