Operation Manual

EVX-530 SEriES OpErating Manual
2
IntrInsIc safety
(
Is
)
InformatIon
IS version of the
EVX-530
series is equipped with any of the following optional units, meets the requirements of
ANSI/UL 913 5th Edition for Class I, II, III, Division 1, Groups C, D, E, F, G, T3C hazardous locations.
Battery Packs:
FNB-V134LIIS-UNI
Speaker Microphone:
MH-66
A4B
VOX Headset:
MH-81
A4B
r
Never charge the battery in the hazard areas.
r
Never install/removal the battery in the hazard areas.
r
Never install/remove the optional unit (includes the Speaker/Microphone and VOX Headset) in the hazard areas.
r
The
EVX-530
shall not be directly installed or used in any process where its enclosure might be electrostati-
cally charged by the rapid ow of a non-conductive media.
r
Ensure that there is no external damage to the radio, antenna or battery before entering the potentially explosive
atmospheres, as it might compromise the safety of the unit. eg an antenna with a damaged end or insulation
must be replaced before use in any potentially explosive atmospheres.
r
Substitution of components may impair intrinsic safety. Installation of
FNB-V134LIIS-UNI
does NOT convert
normal
EVX-530
into IS version.
r
To acquire the IS version of the
EVX-530
series you much select the Intrinsically Safe battery option at the
time of purchase.