Specifications

DMU-2000 DATA MANAGEMENT UNITPage 6
PLEASE READ THIS FIRST
When turning on the transceiver for the first time, please set the local time as soon as possible. If this is not done, the
various functions of the World Clock and Great Circle Map will not operate correctly.
Note: If you wish to add a city to the City List that was programmed at the factory, you will need to supply your own USB
or PS/2 Keyboard. If you utilize one of the pre-loaded cities, a keyboard is not necessary.
You may also set up the local time for other locations, without a keyboard, using the cities that have been pre-loaded at the
factory.
Please note, there are four power switches that must be turned on for the DMU-2000 to operate. They are (1) rear main
power switch of the transceiver, (2) front actual power switch of the transceiver, (3) rear main power switch of the Data
Management Unit, and (4) front panel power switch of the Data Management Unit. The Data Management Unit must be
turned on before pressing the power switch on the front panel of the transceiver.
1. TURNING THE TRANSCEIVER ON
FT-2000 (100 W version)
Press the main
[
POWER
]
switch on the right side of
the rear panel, so that the “
II
II
I” side of the switch is
pressed downward, then press the front panel
[
POWER
]
switch in for two seconds to turn the trans-
ceiver on.
FT-2000D (200 W version)
Press the main
[
POWER
]
switch on the front panel
of the FP-2000, so that the “
II
II
I” side of the switch is
pressed downward, then press the front panel
[
POWER
]
switch in for two seconds to turn the trans-
ceiver on.
FT-950
Turn on the external DC power suppley, and then press
the front panel
[
POWER
]
switch in for two seconds
to turn the transceiver on.
FTDX5000
Press the main
[
POWER
]
switch on the right side of
the rear panel, so that the “
II
II
I” side of the switch is
pressed downward, then press the front panel
[
POWER
]
switch in for two seconds to turn the trans-
ceiver on.
2. TURNING THE DMU-2000 ON
To turn the Data Management Unit on, first
press the main
[
POWER
]
switch (so that
the “
II
II
I” side is pressed downward) on the
rear panel, then press the front panel
[
POWER
]
switch to turn the Data Man-
agement Unit on.
Note: The opening screen will appear on the after-market
monitor and the self-check function of the Data Manage-
ment Unit CPU will begin. When the Data Management
Unit is turned on for the first time, it takes about 50 sec-
onds (for self- checking) until the Data Management Unit
becomes ready to use; however, the next time you turn it
on, it will take around 10 seconds until the Data Manage-
ment Unit is ready for full operation.
Note
In the discussion to follow, reference will be made to various “Function” keys (for example,
[
KEY1
(
MAP
)]
). This
nomenclature refers to the
[
F1
(
CH-1
)]
~
[
DISPLAY
]
keys located along the bottom left edge of the front panel of
the FT-2000/D or
[
1.8
(
1
)]
~
[
24.5
(
8
)]
keys of the FT-950/
FTDX5000 band key
.
The exact function of each key will de-
pend upon the “Page” of the display being viewed on the moni-
tor; therefore, when using the World Map page,
[
KEY1
(
MAP
)]
represents the pressing of the FT-2000/D’s
[
F1
(
CH-1
)]
key
(or the
[
1.8
(
1
)]
key of the FT-950/FTDX5000), with “MAP”
being the function appearing in the “KEY1” position at the bot-
tom edge of the monitor screen.
MANUAL
REFERENCE
[
KEY1
(
xxx
)]
[
KEY2
(
xxx
)]
[
KEY3
(
xxx
)]
[
KEY4
(
xxx
)]
[
KEY5
(
xxx
)]
[
KEY6
(
xxx
)]
[
KEY7
(
xxx
)]
[
KEY8
(
xxx
)]
FT-950
FTDX5000
[
1.8
(
1
)]
[
3.5
(
2
)]
[
7
(
3
)]
[
10
(
4
)]
[
14
(
5
)]
[
18
(
6
)]
[
21
(
7
)]
[
24.5
(
8
)]
FT-2000
FT-2000D
[
F1
(
CH-1
)]
[
F2
(
CH-2
)]
[
F3
(
CH-3
)]
[
F4
(
CH-4
)]
[
F5
(
MEM
)]
[
F6
(
DEC
)]
[
F7
(
P.BACK
)]
[
DISPLAY
]