Specifications
Page 12 FT-950 OPERATING MANUAL
KEY, KEYER, AND COMPUTER-DRIVEN KEYING INTERCONNECTIONS
The FT-950 includes many features for the CW operator. These functions will be detailed in the “Operation” section later.
Besides the built-in Electronic Keyer, two key jacks are provided, one on the front and one on the rear panel, for convenient
connection to keying devices.
The Menu selections allow you to configure the front and rear panel KEY jacks according to the device you wish to
connect. For example, you may connect your keyer paddle to the front panel KEY jack, and use Menu item “
037 A1A F-037 A1A F-
037 A1A F-037 A1A F-
037 A1A F-
TYPETYPE
TYPETYPE
TYPE” for paddle input, and also connect the keying line from your personal computer (which emulates a “straight key”),
to the rear panel KEY jack, and configure the rear panel jack using Menu item “
039 A1A R-TYPE039 A1A R-TYPE
039 A1A R-TYPE039 A1A R-TYPE
039 A1A R-TYPE”.
Both KEY jacks on the FT-950 utilize “Positive” keying voltage. Key-up voltage is approximately +3.3V DC, and key-
down current is approximately 0.3 mA. When connecting a key or other device to the KEY jacks, use only a 3-contact
(“stereo”) 1/4” phone plug; a 2-contact plug will place a short between the ring and (grounded) shaft of the plug, resulting
in a constant “key-down” condition in some circumstances.
INSTALLATION AND INTERCONNECTIONS
KEY
DMU CAT
-TUNE