Specifications
VX-5R OPERATING MANUAL22
VFO LINKING
For split operation on the Amateur bands, the VFO Link feature may be useful.
Set up VFO Split operation, as just described.
Set VFO-A and VFO-B to the same Amateur band (e.g. 430 MHz).
While in the Set mode (used to set up Split operation), rotate the DIAL to select Menu
#5 (“VFO”). This Menu item determines whether VFO tuning will limited to the cur-
rent band “BAND” or allowed to roam freely band-to-band “ALL”.
If the current setting is “ALL”, press the
[
BAND
(
SET
)
AR
]
key to enable modification
of the “VFO” Menu item, then rotate the DIAL to set this Menu selection to “BAND.”
Now press
[
BAND
(
SET
)
AR
]
once more.
Rotate the DIAL to select Menu #10 (“VFO LINK”).
Press the
[
BAND
(
SET
)
AR
]
key to enable activation of the VFO Link feature.
Rotate the DIAL to set this Menu selection to ON.
Press the PTT key to save the new setting and exit to Linked/Split VFO operation.
As you rotate the DIAL, you will observe that both VFO frequencies are changing together.
When you are done with this operating mode, re-enter the Set mode, and set Menu #10 to OFF.
The VFO Link feature requires that (1) VFO-A and VFO-B be set to same
band, (2) Menu #5 (“VFO”) must be set to “BAND.” In other words, the
VFO Link feature cannot activated if VFO-A and VFO-B are not set to the
same band, or if Menu #5 (“VFO”) is set to “ALL.”
CHANGING THE CHANNEL STEPS
The VX-5R’s synthesizer provides the option of utilizing channels steps of 5/9/10/12.5/15/
20/25/50/100 kHz per step, any number of which may be important to your operating
requirements. The VX-5R is set up at the factory with different default steps on each oper-
ating band which probably are satisfactory for most operation. However, if you need to
change the channel step increments, the procedure to do so is very easy.
Press the
[
F/W
]
key, then immediately press the
[
7
(
ST
)
TMP
]
key. This provides a
short-cut to Menu Item #11 (“VFO STEP”).
Rotate the DIAL to select the new channel step size.
Press the PTT key to save the new setting and exit to normal operation.
5 kHz steps are not available on the 50 MHz, “ACT 1,” and “ACT 2” bands;
Use 25 kHz steps to load the 52.525 MHz Simplex Channel into a memory
register, then switch to 10 kHz steps for tuning or scanning of other 6-meter
frequencies. 9 kHz steps are not available, on the “USA” version, on any band.
You may also use the “Set” mode (Menu #11) to change the channel steps. See page 63
for details.
Advanced Operation