Instruction manual
14 Chapter 2 Programming
Continue until all entries have been made. The display can be
sorted by (ID) or (Alias) to facilitate management.
Programmable Parameters
The following parameters are programmable using the
Vertex/Standard supplied CE-73 programming software. Default
values are italicized in brackets to the right of the parameter.
Main Menu
Attack Delay (N/A for end send) 0ms to 1000ms in steps of 50ms.
[Default 300mS]
PTT ANI repeat timer (time since last PTT press. If less, don’t send
PTT ANI) (0=send every PTT; 10s, 20s, 40s, 60s, 90s, 120s)
[Default 0]
TX Time out timer (30s, 60s, 90s, 120s) [Default: 60s]
ANI at START: Send ID at beginning (Y/N) [Default Yes]
ANI at End: Send ID at end (Y/N) [Default No]
PTT Sidetone (beginning send only) (Y/N) [Default Yes]
PTT courtesy tone (Y/N) [Default No]
Enable keypad (Y/N) [Default Yes]
TX Data Level (0,1,2,3) [Default 1]
Allow Acknowledgment Transmissions (Y/N) [Default Yes]
Far End Turn-around Delay (0mS to 2550 mS in 10 mS steps)
[Default 0 mS]
Common – Emergency
Repeat Max: Number of repeat emergency transmissions. (1, 5, 10,
15, 20, forever) [Default =5]
Repeat Period: Time between emergency repeats. (5s, 10, 20,
30s) [Default=10s]
Warning Tone: Emergency TX warning tone (Y/N) [Default No]
Open Microphone Monitor on Emergency TX time (0s to 55s, 5s
steps) [Default 0s]
Open Microphone Monitor on Emergency RX time (0s to 55s, 5s
steps) [Default 0s]
Common – MDC-1200®
PTT ID (1 – DEEE) [Default 1234]
PTT Message value (0x0000-0xFFFF) [Default 0x8001]
Emergency ID (1 – DEEE) [Default 1234]
Emergency Message value (0x0000-0xFFFF) [Default 0x8000]
Call Alert Encode (Long/Short) [Default Short]
Voice Select Call (Y/N) [Default No]
Common – GE Star®
Format type (A through P) [Default B]