Specifications
VX-3R OPERATING MANUAL40
TONE CALLING
(
1750 HZ
)
If the repeaters in your country require a 1750-Hz burst tone for access (typically in Eu-
rope), you can set the MONI switch to serve as a “Tone Call” switch instead. To change the
configuration of this switch, we again use the Set Mode to help us.
1. Press and hold in the
[
TXPO
]
key for one second to enter the Set mode.
2. Rotate the DIAL knob to select Set Mode Item 47:
MM
MM
M/
T-CLT-CL
T-CLT-CL
T-CL.
Note: Do not forget to pull the DIAL knob to rotate the DIAL
knob.
3. Press the
[
TXPO
]
key momentarily to enable adjustment of this
Set Mode Item.
4. Rotate the DIAL knob to select “
T-CALLT-CALL
T-CALLT-CALL
T-CALL” on the display.
5. Press the PTT switch to save the new setting and exit to normal
operation.
To access a repeater, press and hold in the MONI switch for the time specified by the
repeater owner/operator. The transmitter will automatically be activated, and a 1750-Hz
audio tone will be superimposed on the carrier. Once access to the repeater has been gained,
you may release the MONI switch, and use the PTT switch for activating the transmitter
thereafter.
CTCSS/DCS/EPCS OPERATION