User`s guide
AutoTune™ for VX-P820/P920 Rev. C
15
alignment to alignment. This variance
does not affect the radio’s sensitivity in
any way.
Test or Alignment failure Analyzer
measurement.
Occasionally, an alignment or test may
fail because a poor measurement was
received from the analyzer. When this
occurs, first attempt to realign or retest
the radio for the failed item. If an
analyzer measurement was indeed the
reason for the failure, a subsequent
test or alignment should be successful.
Maximum Deviation test or
alignment fails repeatedly
Mistuned Modulation
Balance parameter
The Modulation Balance parameter
may affect the Maximum Deviation
parameter. Use Vertex Standard CE76
tuning software to properly align the
Modulation Balance parameter. Please
see the CE76 Help for instructions on
how to adjust this parameter.
Radio left in AutoTest mode
after test or alignment.
Radio communication
error.
Turn the radio off, then back on.
Table 6-3. Alignment and Test Troubleshooting Chart.